17
CONTROLS & FEATURES
Ground Fault Circuit Interrupter (GFCI)
This generator has two types of Ground Fault Circuit Interrupter (GFCI)
systems, GFCI system
①
and GFCI system
②
.
GFCI System
①
120V-30A, 120V/240V-20A (EB4000X),
120V/240V-30A (EB5000X, EB6500X) RECEPTACLES
If there is a ground-fault current from either A or B receptacle, it will
shut off the power to receptacles A and B.
If this GFCI system
①
activates, the AC circuit breaker will be
switched to OFF position and it will shut off power to all receptacles,
including GFCI system
②
120 V 20 A DUPLEX RECEPTACLES.
GFCI System
②
(120V-20A DUPLEX RECEPTACLE)
If there is a ground-fault current from either 120 V 20 A DUPLEX
RECEPTACLE, then the GFCI System
②
will shut off the power to that
120 V 20 A DUPLEX RECEPTACLE. GFCI system
①
will not be affected.
AC CIRCUIT BREAKER
GFCI SYSTEM
②
(120V-20A DUPLEX RECEPTACLES)
RECEPTACLE A
(120 V 30 A)
GFCI SYSTEM
①
120V-30A, 120V/240V-20A (EB4000X),
120V/240V-30A (EB5000X,EB6500X) RECEPTACLES
(
)
RECEPTACLE B
EB4000X:
120/240 V 20 A
EB5000X, EB6500X:
120/240 V 30 A
(
)