16,40
Machine chassis earth connection
b. 220v/50Hz machines should be connected to an adequate power supply of 220~240V(single
phase) or. The power cable cross-section area should be at least 2.5mm² to ensure adequate
current flow during start-up peak. The connection cable should be no longer than 6m.
c. 380v/50Hz machines should be connected to an adequate three-phase power supply. The power
cable cross-section area should be at least 2.5mm² to ensure adequate current flow during
start-up peak. The connection cable should be no longer than 6m.
Notes:
1. An inadequate power supply may affect machine performance and may lead to damage of key
components such as beater motor, compressor and electronic
controller circuit.
2. Should the need arise to replace the power cable, the new cable must comply with machine
requirements. Any replacement should only be undertaken by a qualified technician.