7
NEW CONSTRUCTION INSTALLATION INSTRUCTIONS (Continued)
8. Attach grille (B) by pinching the mounting springs and
inserting them into the narrow rectangular slots in the
fan housing (A).
Turn on power source. Test the unit.
Mounting
springs
Housing
slots
8
EXISTING CONSTRUCTION INSTALLATION INSTRUCTIONS
Installing the fan housing (A) in an existing building requires an
accessible area (attic or crawl space) above the planned installa-
tion location, as well as existing duct and wiring.
BEFORE INSTALLATION
WARNING: RISK OF ELECTRIC SHOCK!
Ensure the
electricity to the wires you are working on is shut off.
Either remove the fuse or turn off the circuit breaker
before removing the existing bath fan or installing the
new one.
1. Remove existing fan.
1
2. Measure the opening to ensure it is large enough to
accommodate the 7-1/2 in. x 7-1/4 in. dimensions of
the new fan housing (A).
2