12
LIMITED 5-YEAR WARRANTY
If the fan fails due to a defect in materials or workmanship at any time during the first five (5) years of ownership, the manufacturer will
replace it free of charge, postage-paid at their option. This warranty does not cover products that have been abused, altered, damaged,
misused, cut or worn. This warranty does not cover use in commercial applications. Use only manufacturer-supplied genuine warranty
repair replacement parts to repair this fan. Use of non-genuine repair parts will void your warranty. The manufacturer DISCLAIMS all
other implied or express warranties including all warranties of merchantability and/or fitness for a particular purpose. As some states do
not allow exclusions or limitations on an implied warranty, the above exclusions and limitations may not apply. This warranty gives
you specific legal rights, and you may have other rights that vary from state to state.
This warranty is limited to the replacement of defective parts only. Labor charges and/or damage incurred during installation, repair,
replacement as well as incidental and consequential damages connected with the above are excluded. Any damage to this product
as a result of neglect, misuse, accident, improper installation or use other than the purpose SHALL VOID THIS WARRANTY.
Shipping costs for return product as part of a claim on the warranty must be paid for by the customer. Inquiries regarding warranty
claims can be directed to 1-877-319-3757, 7:30 a.m. - 4:30 p.m., CST, Monday - Friday.
TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSE
SOLUTION
The fan seems louder than
it should be.
The CFM is too great.
Be sure the CFM rating on the fan matches the square
footage of your room.
The damper is damaged or not working
properly.
Check the damper to ensure it is opening and closing
properly. If the damper has become damaged, please
call Customer Service.
The bend in the duct is too close to the
fan discharge.
Be sure you do not have any sharp bends in the duct
within 18 in. of the fan discharge.
The fan discharge is reduced to fit a smaller
duct.
Use the recommended size ducting to reduce fan noise.
The fan body is not attached securely.
Be sure the fan is securely attached to the ceiling joists.
The fan is not clearing
humidity from the room.
There is insufficient airflow intake in the room. Be sure a door or window is slightly ajar or open to allow
airflow. The fan is not able to draw air out of the room
without enough airflow.
There is insufficient CFM.
NOTE: Using a tissue is not the correct
method for determining if the fan is operating
properly. If the fan clears steam from the
room within approximately 15 minutes of
completing your shower, then the fan is
operating properly.
Be sure the CFM rating on the fan matches the square
footage of your room.
CARE AND CLEANING (Continued)
5. Attach the grille (B) by pinching the mounting springs and
inserting them into the narrow rectangular slots in the fan
housing (A).
Turn on power source.
5
Mounting
springs
Housing
slots
Printed in China