background image

12

Troubleshooting

1.

The opener doesn't operate from either the

GREEN start button or the remote controls:

• Does the opener have electric power? Plug a lamp into

the outlet. If it doesn't light, check the fuse box.

• Have you disabled all door locks? Review installation

instruction warnings on page 1.

• Is there a build-up of ice or snow under the door? The

door may be frozen to the ground. Remove any
restriction.

• The garage door spring may be broken. Have it

replaced.

2.

Opener operates from the remote control, but not

from the wired wall control (optional accessory):

• Is the wall control lit? If not, reverse the two wires. If

the opener runs, check for a faulty wire connection at
the wall control, a short under the staples, or a broken
wire.

• Are the wiring connections correct? Refer to wired wall

control instructions.

3.

The door operates from the GREEN start button

or wired wall control, but not from the wireless
wall control or remote control:

• If the wired wall control is installed and it is flashing,

ensure the Lock feature is off.

• Program the opener to match the remote control code.

(Refer to Section 17, page 10.) Repeat with all

remotes.

4. The remote control has short range:

• Change the location of the remote control in your car.
• Check to be sure the antenna on the bottom of the

opener extends fully downward.

• Some installations may have shorter range due to a

metal door, foil backed insulation, or metal garage
siding.

5. The garage door opens and closes by itself:

• Be sure that all remote control push buttons are off.
• If the wired wall control (optional accessory) is

installed, remove the bell wire from the wired wall
control terminals and operate from the

GREEN

start

button or remote control. If this solves the problem, the

wired wall control is faulty (replace), or there is an
intermittent short on the wire between the wired wall
control and the opener.

• Clear memory and re-program all wireless wall

controls and remote controls.

6. The door reverses and stops before opening

completely:

• Is something obstructing the door? Is it out of balance,

or are the springs broken? Remove the obstruction or
repair the door.

• Repeat the limit and force setting in Section 12 & 13,

pages 8 & 9 . Repeat safety reverse test after
adjustments (Section 14 page 9).

7. The door reverses for no apparent reason and

opener lights blink for 5 seconds after reversing:

• Check the Protector System (safety beams), if

installed. Correct alignment if the red light on the beam

is solid.

8. The door opens but won't close or reverses while

closing:

• Is something obstructing the door? Pull the manual

release handle. Operate the door manually. If it is
unbalanced or binding, call a trained door systems

• Repeat the limit and force setting in Section 12 & 13,

pages 8 & 9 . Repeat safety reverse test after
adjustments (Section 14 page 9).

• If The Protector System is installed check the beams,

both Red LEDs should be on.

9. The opener strains to operate door:

• The door may be out of balance or the springs may be

broken. Close the door and use the manual release to

disconnect the door. Open and close the door manually.

A properly balanced door will stay in any point of travel

while being supported entirely by its springs. If it does
not, disconnect the opener and call a trained door
systems technician.

10. The opener motor hums briefly, then won't work:

• Check that the door is not in manual release mode,

refer Section 10, page 7.

• The garage door springs may be broken. See above.
• If the problem occurs on the first operation of the
opener, door may be locked. Disable any door locks.

11. The opener won't operate due to power failure:

• Use the manual release handle to disconnect the door.

The door can be opened and closed manually. When
power is restored, re-engage the opener, refer Section
10, page 7.

12. Setting the limits manually:

a. Check that the opener position jumper is correct, refer
Section 7, page 5.
b. Press and hold the

BLACK

button until the orange

indicator light starts flashing slowly then release.
c. Press the

BLACK

button to move the door UP or the

PURPLE

button to move the door DOWN until the door

reaches the desired UP limit. Ensuring there is enough
clearance for your vehicle.
d. Press the

GREEN

start button. This sets the UP limit

and begins closing the door. Immediately press either
the

PURPLE

or the

BLACK

button. The door will stop.

Adjust the desired DOWN limit using the

BLACK

and the

PURPLE

buttons. Check to be sure the door is fully

closed without applying excessive pressure to the door
curtain. Press the

GREEN

start button. This sets the

DOWN limit and begins opening the door. NOTE: If
neither the

BLACK

or the

PURPLE

button is pressed,

the door will reverse off the floor and the DOWN travel
limit will be set automatically.
e. Open and close the door with the

GREEN

start button,

remote control or wall control 2 or 3 times.
• If the door does not stop in the desired UP limit or
reverses before the door stops at the DOWN limit.
Proceed to Setting the Force, Section 13, page 9. If the
door still does not stop at the desired limits is something
obstructing the door? Disengage the opener. Open and
close the door manually. If it is unbalanced or binding,
call a trained door systems technician.
• If the door stops at both the desired UP and DOWN
limits, proceed to Setting the Force.

Содержание HE60R

Страница 1: ...ain Australia Pty Ltd Phone toll free 1800 638 234 Fax toll free 1800 888 121 Chamberlain New Zealand Ltd Phone toll free 0800 637 546 Fax toll free 0800 653 663 www homentry com au This manual contains IMPORTANT SAFETY information DO NOT PROCEED WITH THE INSTALLATION BEFORE READING THOROUGHLY ...

Страница 2: ...0 ...

Страница 3: ...d tested to offer reasonable safe service provided it is installed and operated in strict accordance with the instructions in this manual These safety alert symbols mean WARNING a personal safety or property damage instruction Read these instructions carefully Warning If your garage has no service entrance door a CM1702 outside quick release must be installed This accessory allows manual operation...

Страница 4: ...nded socket and socket wrench 4 30mm socket extension for minimum sideroom installations 5 Drill and 5 5mm drill bit 6 Philips screw driver 7 Marker Pen 1 Instruction manual this document 2 Stop bracket collar 3 Clamp bracket 4 Release handle and cord 5 Remote controls 2 6 Extension poles 2 7 Weight bar 8 Bracket plate 9 Hardware bag 10 Warning Labels 2 Carton Inventory 1 2 ...

Страница 5: ...all diameter extension poles maybe required Different drum and bracket types may result in the minimum side room clearance not being possible and extension poles being required Ensure there is a power point near the opener Typical side room installation Minimum side room installation The maximum allowable door height is 3 5m with a maximum curtain area of 8m door height in metres multiplied by the...

Страница 6: ... opener is to be installed Fit the stop bracket hard against the boss of the door drum Ensure the U bolt holding the door shaft to the door bracket is tightly secured Installing the stop collar 5 Place the weight bar in the centre of the door Use a Pencil to mark the two hole positions Drill two 5 5mm holes through the two marked position then place the weight bar on the inside of the door Use the...

Страница 7: ...oved manually NOTE To re engage the opener pull the release cord across and up For right hand side installations the wire jumper should be in place factory installed Set Opener Position Left or Right hand Engaged Operation Mode Disengaged Manual Release Mode Attaching the Extension Poles if required Insert the extension poles into the gear Align the extension pole holes with the gear holes Using t...

Страница 8: ...e shaft i e 25Nm 28Nm Remove any ropes used FOR LEFT HAND INSTALLATIONS REFER SECTION 7 page 5 Ensure that the opener position jumper wire connector is removed refer Section 7 page 5 Place the opener in manual release mode refer Section 7 page 5 Open the roller door fully For safety tie a rope around the door Ensure that the U bolt on the right hand side of the door is secure Mark the position of ...

Страница 9: ... rope through the hole in the top of the red handle so NOTICE reads right side up as shown Secure with an overhand knot at least 25mm from the end of the rope to prevent slipping Thread the other end of the rope through the loop of the manual release cable Adjust rope length so the handle is no higher than 1 8m above the floor Secure with an overhand knot If the door is greater than 2 5m in height...

Страница 10: ...ss and Hold the Black Limit button until the door reaches the desired open position If set too high adjust down using the Purple Learn button Make sure there is enough room for your vehicle to pass under SET BOTTOM LIMIT Press and Release the Green Start button this sets the UP limit and begins closing the door once the opener starts to move down IMMEDIATELY Press and Hold the Purple Learn button ...

Страница 11: ...nt The garage door must reverse on contact with a 40mm obstacle laid flat on the floor Failure to properly adjust the opener may result in serious personal injury from a closing garage door Operate the door in the down direction The door must reverse on the obstruction If the door stops on the obstruction remove obstruction and repeat limit and force setting Sections 12 13 pages 8 9 Repeat test 14...

Страница 12: ...dy been programmed into your operator Activate the opener only when door is in full view free of obstruction and properly adjusted No one should enter or leave garage whilst door is in motion Do not allow children to operate push button s or remote s Do not allow children to play near the door ADDING remotes using the LEARN Button Press and release the PURPLE learn button on the opener The orange ...

Страница 13: ... opener Remote Control Battery The lithium batteries depending on use and local conditions will last for up to 5 years If transmission range decreases replace the battery Special Features Multi function Control Panel Connect white red wire to the red quick connect terminal and the white wire to the white quick connect terminal The Protector System Safety Beams Connect both white wires to the white...

Страница 14: ...structing the door Pull the manual release handle Operate the door manually If it is unbalanced or binding call a trained door systems Repeat the limit and force setting in Section 12 13 pages 8 9 Repeat safety reverse test after adjustments Section 14 page 9 If The Protector System is installed check the beams both Red LEDs should be on 9 The opener strains to operate door The door may be out of ...

Страница 15: ...Allow a 15 minute cooling period after 4 minutes of continuous operation of the opener Opening the Door Manually Door should be fully closed if possible Weak or broken springs could allow an open door to fall rapidly Property damage or serious personal injury could result The door can be opened manually by pulling the release cord down and across to engage the ball into the cup To re connect the d...

Страница 16: ... from defects in material and or workmanship for a period of 2 YEARS from the date of first purchase from the Seller Please retain your proof of purchase in the unlikely event you require warranty service If during the limited warranty period the Unit fails due to defects in materials or workmanship Chamberlain will provided the defective part or Unit is returned freight and insurance prepaid and ...

Отзывы: