Homentry HE60R Скачать руководство пользователя страница 3

The Protector System must be used for
all installations where the closing force
as measured on the bottom of the door is
over 400N (40kgf).

Excessive force will

interfere with the proper operation of the
Safety Reverse System or damage the
garage door.

After installation, ensure that the parts of
the door do not extend over public
footpaths or roads.

Disengage all existing garage door locks

to avoid damage to garage door.

Install the wireless wall control (or any
additional wall control)

in a location where

the garage door is visible, at a height of
at least 1.5m and out of the reach of
children. The appliance is not intended
for use by young children or infirm
persons without supervision.

Serious

personal injury from a closing garage door
may result from misuse of the opener.
Permanently fasten the

Warning Label

adjacent to the wall control

in a Prominent

Place

as a reminder of safe operating

procedures.

Activate opener only when the door is in
full view, free of obstructions and the
opener is properly adjusted. No one
should enter or leave the garage while
the door is in motion.
Do not allow children to play near the
door.

Disconnect electric power to the garage

door opener before making repairs or
removing covers.

SAVE THESE INSTRUCTIONS

WARNING: Failure to comply with the following instructions may result in serious personal injury or

property damage.

• Read these instructions carefully and follow ALL instructions carefully

• The garage door opener is designed and tested to offer reasonable safe service provided

it is installed and operated in strict accordance with the instructions in this manual.

These safety alert symbols mean

WARNING – a personal safety or property damage

instruction.

Read these instructions carefully.

Warning: If your garage has no service entrance door, a CM1702 outside quick release must be installed.
This accessory allows manual operation of the garage door from outside in case of power failure.

Keep garage door balanced.

Do not let the

garage door opener compensate for a
binding or sticking garage door. Sticking or
binding doors must be repaired. Garage
doors, door springs, brackets and their
hardware are under extreme tension and
can cause serious personal injury.

Do not wear rings, watches or loose
clothing

while installing or servicing a

garage door opener.

To avoid serious personal injury from
entanglement,

remove all ropes, chains

and locks connected to the garage door

before installing the door opener.

Installation

and

wiring

must

be

in

compliance with your local building and
electrical codes.

The safety reverse system test is very
important.

Your garage door

MUST

reverse

on contact with a 40mm obstacle placed on
the floor. Failure to properly adjust the
opener may result in serious personal injury
from a closing garage door.

Repeat the test

once a month and make any necessary
adjustments.

This opener should not be installed in a
damp or wet space.

Take care when operating the manual
release as an open door may fall rapidly
due to weak or broken springs, or being
out of balance.

The drive must not be used on a wicket
door (door within a door)

Start by Reading These Important Safety Instructions

1

Содержание HE60R

Страница 1: ...ain Australia Pty Ltd Phone toll free 1800 638 234 Fax toll free 1800 888 121 Chamberlain New Zealand Ltd Phone toll free 0800 637 546 Fax toll free 0800 653 663 www homentry com au This manual contains IMPORTANT SAFETY information DO NOT PROCEED WITH THE INSTALLATION BEFORE READING THOROUGHLY ...

Страница 2: ...0 ...

Страница 3: ...d tested to offer reasonable safe service provided it is installed and operated in strict accordance with the instructions in this manual These safety alert symbols mean WARNING a personal safety or property damage instruction Read these instructions carefully Warning If your garage has no service entrance door a CM1702 outside quick release must be installed This accessory allows manual operation...

Страница 4: ...nded socket and socket wrench 4 30mm socket extension for minimum sideroom installations 5 Drill and 5 5mm drill bit 6 Philips screw driver 7 Marker Pen 1 Instruction manual this document 2 Stop bracket collar 3 Clamp bracket 4 Release handle and cord 5 Remote controls 2 6 Extension poles 2 7 Weight bar 8 Bracket plate 9 Hardware bag 10 Warning Labels 2 Carton Inventory 1 2 ...

Страница 5: ...all diameter extension poles maybe required Different drum and bracket types may result in the minimum side room clearance not being possible and extension poles being required Ensure there is a power point near the opener Typical side room installation Minimum side room installation The maximum allowable door height is 3 5m with a maximum curtain area of 8m door height in metres multiplied by the...

Страница 6: ... opener is to be installed Fit the stop bracket hard against the boss of the door drum Ensure the U bolt holding the door shaft to the door bracket is tightly secured Installing the stop collar 5 Place the weight bar in the centre of the door Use a Pencil to mark the two hole positions Drill two 5 5mm holes through the two marked position then place the weight bar on the inside of the door Use the...

Страница 7: ...oved manually NOTE To re engage the opener pull the release cord across and up For right hand side installations the wire jumper should be in place factory installed Set Opener Position Left or Right hand Engaged Operation Mode Disengaged Manual Release Mode Attaching the Extension Poles if required Insert the extension poles into the gear Align the extension pole holes with the gear holes Using t...

Страница 8: ...e shaft i e 25Nm 28Nm Remove any ropes used FOR LEFT HAND INSTALLATIONS REFER SECTION 7 page 5 Ensure that the opener position jumper wire connector is removed refer Section 7 page 5 Place the opener in manual release mode refer Section 7 page 5 Open the roller door fully For safety tie a rope around the door Ensure that the U bolt on the right hand side of the door is secure Mark the position of ...

Страница 9: ... rope through the hole in the top of the red handle so NOTICE reads right side up as shown Secure with an overhand knot at least 25mm from the end of the rope to prevent slipping Thread the other end of the rope through the loop of the manual release cable Adjust rope length so the handle is no higher than 1 8m above the floor Secure with an overhand knot If the door is greater than 2 5m in height...

Страница 10: ...ss and Hold the Black Limit button until the door reaches the desired open position If set too high adjust down using the Purple Learn button Make sure there is enough room for your vehicle to pass under SET BOTTOM LIMIT Press and Release the Green Start button this sets the UP limit and begins closing the door once the opener starts to move down IMMEDIATELY Press and Hold the Purple Learn button ...

Страница 11: ...nt The garage door must reverse on contact with a 40mm obstacle laid flat on the floor Failure to properly adjust the opener may result in serious personal injury from a closing garage door Operate the door in the down direction The door must reverse on the obstruction If the door stops on the obstruction remove obstruction and repeat limit and force setting Sections 12 13 pages 8 9 Repeat test 14...

Страница 12: ...dy been programmed into your operator Activate the opener only when door is in full view free of obstruction and properly adjusted No one should enter or leave garage whilst door is in motion Do not allow children to operate push button s or remote s Do not allow children to play near the door ADDING remotes using the LEARN Button Press and release the PURPLE learn button on the opener The orange ...

Страница 13: ... opener Remote Control Battery The lithium batteries depending on use and local conditions will last for up to 5 years If transmission range decreases replace the battery Special Features Multi function Control Panel Connect white red wire to the red quick connect terminal and the white wire to the white quick connect terminal The Protector System Safety Beams Connect both white wires to the white...

Страница 14: ...structing the door Pull the manual release handle Operate the door manually If it is unbalanced or binding call a trained door systems Repeat the limit and force setting in Section 12 13 pages 8 9 Repeat safety reverse test after adjustments Section 14 page 9 If The Protector System is installed check the beams both Red LEDs should be on 9 The opener strains to operate door The door may be out of ...

Страница 15: ...Allow a 15 minute cooling period after 4 minutes of continuous operation of the opener Opening the Door Manually Door should be fully closed if possible Weak or broken springs could allow an open door to fall rapidly Property damage or serious personal injury could result The door can be opened manually by pulling the release cord down and across to engage the ball into the cup To re connect the d...

Страница 16: ... from defects in material and or workmanship for a period of 2 YEARS from the date of first purchase from the Seller Please retain your proof of purchase in the unlikely event you require warranty service If during the limited warranty period the Unit fails due to defects in materials or workmanship Chamberlain will provided the defective part or Unit is returned freight and insurance prepaid and ...

Отзывы: