45
7.1.3 Behavior after inserting the batteries
After inserting the battery, the sensor will run a self-
test. This runs for approx. 2 seconds. The initializa-
tion runs next. The completion is indicated with the
LED test display: red, green, orange, each for a half
second.
If an error occurs, it is indicated with red
flashing!
The sensor then sends a status message - indicated
by the device LED illuminated in orange. This is follo-
wed by either read or green flashing when the sensors
have been taught, depending on whether the reception
has been confirmed or not.
One long flash, two short flashes,
pause (repeated 2 times)
Battery power
too low
One long flash, one short flash, pause
(infinite)
Sensor defective
If the battery power is low, as long as the power
level allows, the sensor is activated and is ready for
operation. Depending on the requirements, the battery
may recover and send again many times after a short