43
Start-up
Before installation, please note the device num-
ber (SGTIN) labelled on the device as well as the
exact application purpose in order to make later
allocation easier. You can also find the device
number on the QR code sticker supplied.
To install the input module on a DIN rail within a distribu-
tion board, please proceed as follows:
• Disconnect the power distribution panel and
cover any live parts, if required (see hazard
information).
• Remove the cover of the power distribution panel.
• Place the input module onto the DIN rail (
see
fig. 3
). Make sure that you can read the letters on
the device and display and that the connecting
terminals of channel 1 to 8 and 17 to 28 are at
the top.
• During installation, make sure that the locating
springs engage properly and that the device is
securely seated on the rail.
• Wire the device according to the connecting
diagram in
figure 2
.
• Connect the bus using the supplied connecting
cable (
see figure 4
).
• Use the supplied bus blind plug, if bus connection
1
(E)
or bus connection 2
(F)
are not needed.
• Reattach the cover of the power distribution panel.
• Switch the fuse of the power circuit on again to