39
Start-up
5
Start-up
5.1
Installation instructions
Please observe the hazard information in section
„2 Hazard information“ on page 28 during in-
stallation.
Please note the insulation stripping length of the
conductor to be connected, indicated on the
device.
The inputs are not disconnected from the mains
voltage but provide the bus voltage. Connected
push-buttons, switches or other switching ele-
ments must be specified for a rated voltage of at
least 26 V.
For electrical safety reasons, only the supplied
Homematic IP Wired Bus Cable may be used for
connecting the device to the Homematic IP
Wired bus. Furthermore, an eQ-3 Homematic IP
Wired Bus Cable with other lengths (available as
accessory) can be used.
Rigid cables can be plugged directly into the
clamp terminal (push-in technology). To connect
flexible cables or to loosen any kind of conduc-
tors, the white actuation lever at the top of the
clamp has to be pressed.