48
49
Start-up
Start-up
Step 1
Switch off the fuse of the power circuit.
Step 2
If necessary, pull the rocker off the frame
of the relevant switch. Then pull the
frame off the switch together with the
clamping/retaining piece. The clamping/
retaining piece can be transparent, grey
or black depending on the manufacturer,
and holds the frame onto the switch.
To make removal easier, a flat, pointed
object such as a slotted screwdriver can
be used.
Step 3
Release the wiring and remove the exist-
ing switch if necessary.
Step 4
On-off circuit:
Connect the conduc-
tor to the lamp/luminaire at connecting
terminal 2
(D)
.
Two-way circuit:
Connect the two cor-
responding supply cables to the two-way
switch at connecting terminals 1
(C)
and
2
(D)
.
Intermediate switch circuit:
Connect the
two corresponding supply cables to the
intermediate switch circuit at connecting
terminals 1
(C)
and 2
(D)
.
Step 5
Connect the phase conductor to con-
necting terminal L
(B)
.
Step 6
Connect the neutral conductor to con-
necting terminal N
(E)
.
Step 7
Connect the neutral conductor of the
lamp / luminaire to the neutral conductor
of the house installation.
Step 8
Secure the switch actuator and meter to
the flush-mounted box using the pro-
vided screws. Please note that the system
button
(A)
of the actuator must be at the
top left during installation.
Step 9
Fit the adapter to the rocker (
see figure 5
).
Step 10
Now secure the rocker with the adapter
in the frame on the actuator.
Position the adapter so that both latching
lugs fit into the existing elongated holes
(
see figure 6
).
Step 11
Switch the fuse of the power circuit back
on again.
Step 12
Now the switch actuator and meter can
be taught-in to the Homematic IP Access
Point (see „6.3 Teaching-in“ on page 50).