B. Drive 3/4” or 1/2” locking screws through frame 

holes into window sash (Fig.8).

C. To secure lower sash in place, attach right angle 

sash lock with 3/4” or 1/2” screw as shown (Fig.9).

D. Cut Window sash seal foam and insert it in the 

space between the upper and lower sashes (Fig.10).

INSTALLATION INSTRUCTIONS

IF A/C IS BLOCKED BY STORM WINDOW

Add wood as shown in Fig. 11, or remove storm 

window before air conditioner is installed.
If Storm Window Frame must remain, be sure the 

drain holes or slots are not caulked or painted shut. 

Accumulated Rain Water or Condensation must be 

allowed to drain out.

• Turn AC off, and disconnect power cord.
• Remove sash seal from between windows, 

and unscrew safety sash lock.

• Remove screws installed through frame and 

frame-lock.

• Close (slide) side panels into frame.
• Keeping a firm grip on air conditioner, raise 

sash and carefully remove.

• Be carefully not to spill any remaining water 

while lifting unit from window. Store parts 

WITH air conditioner.

Fig. 8

Fig. 9

Fig. 10

Fig. 11

FOAM SEAL

SASH

1-1/2” min

(38mm)

Storm window 

frame or other 

obstruction.

Board thickness 

as required, for 

proper pitch to 

rear, along entire 

sill. Fasten with 

nails or screws.

Removing AC From Window

Содержание HME020003N

Страница 1: ...Window Air Conditioner 5000 BTU Unit Before using your Air Conditioner please read this manual ...

Страница 2: ...mportant Safety Instructions 4 6 Installation Instructions 7 10 Normal Sounds 11 Air Directional Louvers 11 Air Conditioner Features 11 12 Care and Cleaning 12 Troubleshooting Tips 13 14 Warranty 15 USER MANUAL TABLE OF CONTENTS ...

Страница 3: ...e appliance Don t forget to register your product at www home family reg for updates coupons and other relevant information Although greatly appreciated product registration is not required to activate any warranty CONGRATULATIONS ...

Страница 4: ... power circuit Incorrect installation may cause fire or electric shock Always ensure effective grounding Unplug the unit if any strange sounds smell or smoke comes from it Do not damage or use an unspecified power cord If the power cord is damaged contact hOme customer service at 1 800 898 3002 in order to avoid a hazard Do not direct airflow at room occupants only Do not modify power cord length ...

Страница 5: ...g the power plug out and contact a qualified service technician Ventilate the room well when used together with a stove etc An oxygen shortage may occur Do not use for special purposes Do not use this air conditioner to preserve precision devices food pets plants and art objects It may cause deterioration of quality etc Ensure that the installation bracket of the outdoor appliance is not damaged d...

Страница 6: ...his manual Save this manual for possible future use in removing or installing this unit When handling the air conditioner be careful to avoid cuts from sharp metal fins on front and rear coils Electrical Information The complete electical rating of your new room air conditioner is stated on the serial plate Refer to the rating when checking the electrical requirements Be sure the air conditioner i...

Страница 7: ...g this air conditioner Your air conditioner is designed to install in standard double hung windows with opening widths of 23 to 36 inches Do not under any circumstances cut or remove the third ground prong from the power cord Do not change the plug on the power cord of the air conditioner Aluminum house wiring may present special problems consult a qualified electircian When handling unit be caref...

Страница 8: ...are offset to provide the proper pitch to the rear of 5 16 This is necessary for proper condensed water utilization and drainage If you are not using the Side Panels for any reason this pitch to the rear must be maintained C Align the hole in the top rail with those in the top of the unit as shown in Fig B D Secure the top rail to the unit with the 3 8 Screws as shown in Fig C A Place unit on floo...

Страница 9: ... blocks AC see Fig 11 NOTE Check that air conditioner is tilted back about 5 8 to 3 4 tilted about 3O to 4O downward to the outside After proper installation condensate should not drain from the overflow drain hole during normal use correct the slope otherwise A Keep a firm grip on the air conditioner carefully place the unit into the window opening so the bottom of the air conditioner frame is ag...

Страница 10: ...re not caulked or painted shut Accumulated Rain Water or Condensation must be allowed to drain out Turn AC off and disconnect power cord Remove sash seal from between windows and unscrew safety sash lock Remove screws installed through frame and frame lock Close slide side panels into frame Keeping a firm grip on air conditioner raise sash and carefully remove Be carefully not to spill any remaini...

Страница 11: ...ioner follow these steps 1 Set the thermostat to the highest number coldest or cooler setting 2 Set the selector control to the highest COOL setting 3 Adjust the louver for comfortable air flow see Air Directional Louvers 4 Once the room has cooled adjust the thermostat to the setting you find most comfortable 5 Make sure that the air flow inside and outside are not obstructed by anything Air Dire...

Страница 12: ...ost on the cooling coils If you plan to store the air conditioner during the winter remove it carefully from the window according to the installation instructions Cover it with plastic or return it to the original carton Remove the filter by sliding out from the right hand side Wash the filter using liquid dishwashing detergent and warm water Rinse filter thoroughly Gently shake excess water from ...

Страница 13: ...ition louvers for better air distribution Front of units is blocked by drapes blinds furniture etc restricts air distribution Clear blockage in front of unit Doors windows registers etc Open cold air escapes Close doors windows registers Unit recently turned on in hot room Allow additional time to remove Stored heat from walls ceiling floor and furniture Dirty air filter air restricted Clean air f...

Страница 14: ...e remote control within 20 feet 180O radius of the front of the unit Remote control signal obstructed Remove obstruction Set temperature too low Increase set temperature Problem Water dripping INSIDE when unit is cooling Water dripping OUTSIDE when unit is cooling Remote Sensing Deactivating Prematurely some models Room too cold Before calling for service review this list It may save your time and...

Страница 15: ...usehold use The hOme warranty covers all costs related to restoring the proven defective product through repair or replacement of any defective part and necessary labor so that it conforms to its original specifications A replacement product may be provided instead of repairing a defective product HOme s exclusive obligation under this warranty is limited to such repair or replacement A receipt in...

Страница 16: ...SKU HME020003N PART HME020003MNL 2016 hOme Technologies LLC 37 East 18 Street 7th Floor New York NY 10003 All rights reserved hOme Printed in China HOUSEHOLD USE ONLY ...

Отзывы: