Holtkamp Electronics MAXI 3200 techn. stand 09.2017 4025_09.2017 V09.2019
- 9 -
8.4 Electrical connection
The electrical connection can be carried out only by
authorized and qualified personnel!
The electrical connection can only be carried out by the local
VDE regulations. With a permanent connection, an all pole mains
separator with at least 3 mm contact gap must be used. Before
starting the electric circuit must be disconnected. Shut down the
mains input by activating the separator switch, remove the fuse
or release the main safety fuse. Mains and low voltage cable
must be spaced apart. Low voltage cables should be generally
spaced as screened cables.
After the electrical connection the MAXI can completed.
Mains and low voltage cables must be laid separately from each
other. Low voltage cables should be laid generally as shielded
cables. After the electrical connection has been made, the MAXI
can be completed again.
8 Installation
8.1 Installation notes
Through micro-electronics, the "MAXI 3200" reaches a high reli
-
ability in the daily use. This can only be reached if the installation
takes place expertly. Heed with the installation necessarily, …
● She must after VDE- rule and from electro experts is en
forced.
●
With counters with 230V is necessary the connection of the
protection-leader and with counters with 24V is required the
protection-ladder as function-earth.
● The floor must antistatic and conductive, that not statically
loads.
8.2 Mounting notes
● The MAXI 3200 were designed for the montage on the wall
and for partial into the wall.
● The coin timer must be well fast. For this, please use the
attachments of rear from casing.
● The device is cabled by means of threaded metric threads
on the bottom or rear.
●
The MAXI 3200 corresponds to the protection-type IP20
and can be used only in dry rooms/areas..
● The MAXI 3200 must be installed vertically and horizontally
exactly. The inclination should not exceed 2° in any direction.
8.3 Mounting instructions
● Disconnect the power supply by moving the corresponding
disconnector, with fuse or even by triggering of the protecti-
ve switch.
● Unlock the lock of coin acceptance and remove the coin
flap.
● Loosen the two front panel screws and lift the front panel.
● Disconnect the electrical connectors and remove the front
panel completely.
● Using a spirit level, align the bottom of the housing horizon-
tally and vertically and mark the three mounting holes.
● Drill the holes and insert suitable dowels. Make
the electrical connection through the holes in the rear-
wall or from below. Metric thread (M20) fittings are required
when wiring from below.
● Then fix the housing with suitable screws. Now restore the
electrical connections. Now replace the front panel and
screw it in place.Insert the coin box, then place the removel
of coins, fold it and lock it.
Control cable and remote
start connection have to be
kept away from each other.