Holtkamp Electronics MAXI 3200 techn. stand 09.2017 4025_09.2017 V09.2019
- 17 -
13.2 Special errors
4 points in the display of the MAXI 3200 are flashing and this
means, there is a special error. Under point 7 in the book
-
keeping-statistics menu you can read out the error number.
Error code
Possible causes
Remedy
1
Memory delete, battery empty
Change the battery
2
Memory defect
Change the electronic board
3
Memory defect
Change the electronic board
4
Memory defect
Change the electronic board
5
Memory defect
Change the electronic board
6
Coin switch-sabotage
Micro-switch of the coin tester are closed to
long– Sabotage is possibility
Clean up the coin tester and make sure, that there can not be
any sabotage
7
Safety loop during impulse operation has broken
Error is possible only during decrement function
Check the cable
10
Impulse counter has an overflow
Maximum from 999 is reached
Delete impulse counter
11
Operating hours counter has an overflow
Maximum from 999 is reached
Delete operating hours counter
12
Service activations counter has an overflow
Maximum from 999 is reached.
Delete service activations counter
15
Memory delete, because irregular counter rea
-
dings are noticed
Register and delete the error indicator
16
Not defined switching state on the board - ser
-
vice needed
It is possible, that the connection is wrong.
Please ask for technical support
In the below list you can see, what is behind the code. If you go to
the bookkeeping-statistics menu the flashing is automatically off.
Electricity installations make leave only by an electrical
specialist!