12 Not programmable special equipments
12.1 Contactor 2 x 20 A
The contactor offers the possibility, to increase the switching po
-
wer of the MAXI. If you have ordered your MAXI with a contactor,
it will be installed on the SB frame inside on the rear wall of the
casing.
Time electronic
Time stop
electronics
Coin acceptor
Main relay A1 PE N L
Contactor 2 x 20 A
(Special equipment)
12.2 Connection for time stop
The extra connection for time stop offers the possibility, to inter
-
rupt the main time count-down with an external switch (e.g. flow
sensor). If your MAXI has been ordered with an extra connection
for time stop, you will find on the SB frame, on the inside rear
wall of the casing a 2-pole screw-terminal to connect an external
switch (potential free closing contact). This special equipment
can not be ordered with the special equipments cleaning button
or short time impulse for washing machine door opener.
12.3 Current-dependent time stop
The current-dependent time stop offers the possibility, to dis
-
connect the main time depended on the power input of the
connected device. If the power input is e. g. under 40, 80 or 100
mA (as ordered), then the main time count-down will be inter
-
rupted.
12.4 Potential free relay contact
If you have ordered your MAXI with potential free relay contacts,
the closing contact of the main relay or the run-out relay, will be
voltage free on the screw terminals. These terminals are on the
SB frame, inside the rear wall of the casing.
12.5 Current-dependent time stop
The current-dependent time stop offers the possibility of interrupt
-
ing the main time sequence depending on the current consump
-
tion of the connected device. If the current consumption is e.g.
Below 40, 80 or 100 mA or 130 mA (according to your order), the
main timeout will be interrupted.