background image

Datasheet

The Sure Cross

®

 wireless system is a radio frequency network with integrated I/O that operates in most environments to eliminate

the need for wiring runs.

Wireless industrial I/O device with two configurable asynchronous counter inputs and

four NMOS outputs

Selectable transmit power levels of 250 mW or 1 Watt for 900 MHz models and 65 mW

for 2.4 GHz models

DIP switches for user configuration

Frequency Hopping Spread Spectrum (FHSS) technology ensures reliable data delivery

within the unlicensed Industrial, Scientific, and Medical (ISM) band

Transceivers provide bidirectional communication between the Gateway and Node,

including fully acknowledged data transmission

Lost RF links are detected and relevant outputs set to user-defined conditions

Field-wireable terminals for wiring I/O

Important: Please download the complete Performance Gateway or Node technical documentation, available in

multiple languages, from www.bannerengineering.com for details on the proper use, applications, Warnings,

and installation instructions of this device.

Important: Por favor descargue desde www.bannerengineering.com toda la documentación técnica de los

Performance Gateway or Node, disponibles en múltiples idiomas, para detalles del uso adecuado, aplicaciones,

advertencias, y las instrucciones de instalación de estos dispositivos.

Important: Veuillez télécharger la documentation technique complète des Performance Gateway or Node sur

notre site www.bannerengineering.com pour les détails sur leur utilisation correcte, les applications, les notes

de sécurité et les instructions de montage.

WARNING:

Do not use this device for personnel protection

Using this device for personnel protection could result in serious injury or death.

This device does not include the self-checking redundant circuitry necessary to allow its use in
personnel safety applications. A device failure or malfunction can cause either an energized (on) or de-
energized (off) output condition.

Important:

Never operate a 1 Watt radio without connecting an antenna

Operating 1 Watt radios without an antenna connected will damage the radio circuitry.

To avoid damaging the radio circuitry, never apply power to a Sure Cross

®

 Performance or Sure Cross

MultiHop (1 Watt) radio without an antenna connected.

Important:

Electrostatic discharge (ESD) sensitive device

ESD can damage the device. Damage from inappropriate handling is not covered by warranty.

Use proper handling procedures to prevent ESD damage. Proper handling procedures include leaving
devices in their anti-static packaging until ready for use; wearing anti-static wrist straps; and assembling
units on a grounded, static-dissipative surface.

Models

Model

Frequency

Inputs and Outputs

DX80N9X1S-P16E

900 MHz ISM Band

Inputs: Two configurable asynchronous counters
Outputs: Four NMOS

DX80N2X1S-P16E

2.4 GHz ISM Band

Sure Cross

®

 Performance Universal Counter

P16E Node

 

 

Original Document

199134 Rev. D

8 November 2019

199134

Содержание Sure Cross P16E Series

Страница 1: ...mentation technique complète des Performance Gateway or Node sur notre site www bannerengineering com pour les détails sur leur utilisation correcte les applications les notes de sécurité et les instructions de montage WARNING Do not use this device for personnel protection Using this device for personnel protection could result in serious injury or death This device does not include the self chec...

Страница 2: ...to the Gateway 4 Form the wireless network by binding the Nodes to the Gateway If the binding instructions are not included in the datasheet refer to the product manual for binding instructions 5 Observe the LED behavior to verify the devices are communicating with each other For housed models the Gateway s LED 1 is solid green and the Node s LED 1 flashes green to indicate it is communicating wit...

Страница 3: ...e Input Type PNP OFF ON Counter Discrete Value Input Type Float 1 V Threshold ON OFF Counter Discrete Value Input Type Float 300 mV Threshold ON ON Sample Report Rate 64 Seconds OFF OFF Sample Report Rate 16 Seconds OFF ON Sample Report Rate 4 Seconds ON OFF Sample Report Rate Modbus or UCT Configured ON ON Debounce Enabled OFF Debounce Disabled ON Counter 2 Input Type Event OFF Counter 2 Input Ty...

Страница 4: ... for 2 4 GHz is fixed at about 65 mW EIRP 18 dBm making the 2 4 GHz Performance models automatically compatible with older 2 4 GHz models Wire for Power and I O XD4 XC4 CT2 PWR DO2 GND DO6 XC4 XC3 GND PWR DO5 DO1 XD3 XC3 CT1 CT1 Counter input 1 CT2 Counter input 2 DO1 NMOS output 1 DO2 NMOS output 2 DO5 NMOS output 5 DO6 NMOS output 6 PWR Power for sensors Counter Input Wiring for PNP Sensors Coun...

Страница 5: ...21 0x1401 to clear counter 1 2 Write 5122 0x1402 to clear counter 2 3 Write 5123 0x1403 to clear counters 1 and 2 When you are not using a host controlled system a transition from 0 to 1 on the Node s output registers is needed to clear the counter Use this method on Gateway IO mapping to map inputs such as a push button to clear counter values 1 Write output register 13 from 0 to 1 to clear count...

Страница 6: ... Node 8 Instance 112 N14 NMOS OUT 1 0 1 0 1 10 10 Node 16 1 Node 8 NMOS OUT 2 0 1 0 1 11 11 Node 16 2 Node 8 NMOS OUT 5 0 1 0 1 12 12 Node 16 3 Node 8 NMOS OUT 6 0 1 0 1 13 13 Node 16 4 Node 8 Clear Counter 1 0 1 0 1 14 14 Node 16 5 Node 8 Clear Counter 2 0 1 0 1 15 15 Node 16 6 Node 8 Control Message 16 16 Node 16 7 Node 8 Reserved Installing or Replacing the Battery DX80 E Models To replace the ...

Страница 7: ...rete Input OFF Condition PNP Less than 5 V NPN Greater than 2 V or open Counter Input Event counter Input rating 1 Hz to 10 kHz For battery powered devices the recommended input rating is less than 1 kHz Rate frequency counter 1 Hz to 10 kHz Debounce select will filter the higher frequencies Thresholds PNP NPN See Discrete Input Conditions Float Selectable 1 V 300 mV Wiring Access Two 1 2 inch NPT...

Страница 8: ... OF PERFORMANCE COURSE OF DEALING OR TRADE USAGE This Warranty is exclusive and limited to repair or at the discretion of Banner Engineering Corp replacement IN NO EVENT SHALL BANNER ENGINEERING CORP BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS EXPENSES LOSSES LOSS OF PROFITS OR ANY INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE US...

Отзывы: