![Banner Sure Cross P16E Series Скачать руководство пользователя страница 7](http://html.mh-extra.com/html/banner/sure-cross-p16e-series/sure-cross-p16e-series_manual_471815007.webp)
For outside or high humidity environments, dielectric grease may be applied to the battery terminals to
prevent moisture and corrosion buildup.
As with all batteries, these are a fire, explosion, and severe burn hazard. Do not burn or expose them to
high temperatures. Do not recharge, crush, disassemble, or expose the contents to water.
For non-hazardous locations, the replacement battery is model BWA-BATT-011. For non-hazardous or
hazardous locations, the replacement battery is Xeno model XL-205F, Banner model BWA-BATT-001.
For pricing and availability, contact Banner Engineering.
Specifications
Performance Radio Specifications
Radio Range
1
900 MHz, 1 Watt: Up to 9.6 km (6 miles)
2.4 GHz, 65 mW: Up to 3.2 km (2 miles)
Antenna Minimum Separation Distance
900 MHz, 1 Watt: 4.57 m (15 ft)
2.4 GHz, 65 mW: 0.3 m (1 ft)
Radio Transmit Power
900 MHz, 1 Watt: 30 dBm (1 W) conducted (up to 36 dBm EIRP)
2.4 GHz, 65 mW: 18 dBm (65 mW) conducted, less than or equal to 20 dBm
(100 mW) EIRP
Spread Spectrum Technology
FHSS (Frequency Hopping Spread Spectrum)
900 MHz Compliance (1 Watt)
FCC ID UE3RM1809: FCC Part 15, Subpart C, 15.247
IC: 7044A-RM1809
2.4 GHz Compliance
FCC ID UE300DX80-2400: FCC Part 15, Subpart C, 15.247
RED Directive 2014/53/EU
IC: 7044A-DX8024
Antenna Connection
Ext. Reverse Polarity SMA, 50 Ohms
Max Tightening Torque: 0.45 N·m (4 lbf·in)
Link Timeout
Gateway: Configurable via User Configuration Software
Node: Defined by Gateway
P16E Performance Node Specifications
Supply Voltage
10 V DC to 30 V DC (Outside the USA: 12 V DC to 24 V DC, ± 10%) with
integrated battery backup
Discrete Input
Rating: 3 mA max current at 30 V DC
Sample / Report Rates: DIP switch configurable
Discrete Input ON Condition
PNP: Greater than 10 V
NPN: Less than 0.7 V
Discrete Input OFF Condition
PNP: Less than 5 V
NPN: Greater than 2 V or open
Counter Input
Event counter: Input rating 1 Hz to 10 kHz (For battery powered devices, the
recommended input rating is less than 1 kHz)
Rate (frequency) counter: 1 Hz to 10 kHz
Debounce select will filter the higher frequencies
Thresholds:
PNP/NPN: See Discrete Input Conditions
Float: Selectable (1 V / 300 mV)
Wiring Access
Two 1/2-inch NPT
Current Draw at 3.6 V dc
900 MHz, 1 Watt: Average Runtime 320 µA
900 MHz, 250 mW: Average Runtime 270 µA
2.4 GHz, 65 mW: Average Runtime 250 µA
Housing
Polycarbonate housing and rotary dial cover; polyester labels; EDPM rubber
cover gasket; nitrile rubber, non-sulphur cured button covers
Mounting: 1/4-inch or M7 (SS M7 hardware included)
Max. Tightening Torque: 0.56 N·m (5 lbf·in)
Interface
Two bi-color LED indicators
Two buttons
Six character LCD
Certifications
(CE approval only
applies to 2.4 GHz
models)
(NOM approval only
applies to 900 MHz
models)
Environmental Specifications for the E Housing
Operating Conditions
–40 °C to +85 °C (–40 °F to +185 °F) (Electronics); –20 °C to +80 °C (–4 °F to
+176 °F) (LCD)
95% maximum relative humidity (non-condensing)
Radiated Immunity: 10 V/m (EN 61000-4-3)
Shock and Vibration
IEC 68-2-6 and IEC 68-2-27
Shock: 30g, 11 millisecond half sine wave, 18 shocks
Vibration: 0.5 mm p-p, 10 to 60 Hz
Environmental Ratings
IEC IP65
Refer to the Sure Cross
®
Wireless I/O Networks Instruction Manual (p/n
) for installation and waterproofing instructions.
Operating the devices at the maximum operating conditions for
extended periods can shorten the life of the device.
1
Radio range is with the 2 dB antenna that ships with the product. High-gain antennas are available, but the range depends on the environment and line of sight. Always verify your wireless
network's range by performing a Site Survey.
Sure Cross
®
Performance Universal Counter P16E Node
P/N 199134 Rev. D
www.bannerengineering.com - Tel: + 1 888 373 6767
7