HT82M75REW/HT82K75REW
Rev. 1.00
58
June 11, 2010
RF Transceiver Application Guide
Some typical applications are described in this section to help user gains more understanding of the operation of the
RF Transceiver.
RF Transceiver Hardware Connection
A typical application connection is shown in Application Circuit section. The MCU host serves as a master role, and the
RF Transceiver serves as a slave role. For more information, refer to the Application Circuit section.
RF Transceiver Initialization
After the RF Transceiver is powered up, some registers need to be configured before the data transmission or recep-
tion. The procedure is described as below.
·
Procedure List
Parameter
Symbol
Min.
Max.
Unit
Conditions
SREG
0x26
GATECLK
Enable SPI sync function
20
SREG
0x17
PACON1
Increase PAON time
08
SREG
0x18
FIFOEN
Increase TXON time
94
SREG
0x2E
TXPEMISP
VCO calibration period
95
LREG
0x200
RFCTL0
RF optimized control
01
LREG
0x201
RFCTL1
RF optimized control
02
LREG
0x202
RFCTL2
RF optimized control
E0
LREG
0x204
RFCTL4
RF optimized control
06
LREG
0x206
RFCTL6
RF optimized control
C0
1M bps
LREG
0x207
RFCTL7
RF optimized control
F0
1M bps
LREG
0x208
RFCTL8
RF optimized control
8C
LREG
0x23D
GPIODIR
For Setting GPIO to Output
00
LREG
0x250
RFCTL50
RF optimized control
07
DC-DC OFF
LREG
0x251
RFCTL51
RF optimized control
C0
LREG
0x252
RFCTL52
RF optimized control
01
LREG
0x259
RFCTL59
RF optimized control
00
LREG
0x273
RFCTL73
RF optimized control
40
LREG
0x274
RFCTL74
RF optimized control
C6
DC-DC OFF
LREG
0x275
RFCTL75
RF optimized control
13
LREG
0x276
RFCTL76
RF optimized control
07
SREG
0x32
INTMSK
Enable all interrupt
00
SREG
0x2A
SOFTRST
Baseband Reset
02
SREG
0x36
RFCTL
RF Reset
04
Reset RF State Machine
SREG
0x36
RFCTL
RF Reset
00
Release RF State Machine