Rev. 1.00
12
March 24, 2020
Rev. 1.00
13
March 24, 2020
BS83A04C
4-Key Enhanced Touch I/O Flash MCU
BS83A04C
4-Key Enhanced Touch I/O Flash MCU
Operating Frequency Characteristic Curves
System Operating Frequency
Operating Voltage
8MHz
1.8V
~ ~
5.5V
~ ~
~ ~
System Start Up Time Characteristics
Ta=-40°C~85°C
Symbol
Parameter
Test Conditions
Min. Typ. Max. Unit
V
DD
Conditions
t
SST
System Start-up Time
Wake-up from condition where f
SYS
is off
— f
SYS
=f
H
~f
H
/64, f
H
=f
HIRC
—
16
—
t
HIRC
— f
SYS
=f
SUB
=f
LIRC
—
2
—
t
LIRC
System Start-up Time
Wake-up from condition where f
SYS
is on
— f
SYS
=f
H
~f
H
/64, f
H
=f
HIRC
—
2
—
t
H
— f
SYS
=f
SUB
=f
LIRC
—
2
—
t
SUB
System Speed Switch Time
FAST to SLOW Mode or
SLOW to FAST Mode
— f
HIRC
switches from off → on
—
16
—
t
HIRC
t
RSTD
System Reset Delay Time
Reset source from Power-on reset or LVR
hardware reset
— RR
POR
=5V/ms
42
48
54
ms
System Reset Delay Time
WDTC/RSTC software reset
—
—
System Reset Delay Time
Reset source from WDT overflow
—
—
14
16
18
ms
t
SRESET
Minimum Software Reset Width to Reset
—
—
45
90
120
μs
Note: 1. For the System Start-up time values, whether f
SYS
is on or off depends upon the mode type and the chosen
f
SYS
system oscillator. Details are provided in the System Operating Modes section.
2. The time units, shown by the symbols t
HIRC
, t
SYS
etc. are the inverse of the corresponding frequency values
as provided in the frequency tables. For example: t
HIRC
=1/f
HIRC
, t
SYS
=1/f
SYS
etc.
3. If the LIRC is used as the system clock and if it is off when in the SLEEP Mode, then an additional LIRC
start up time, t
START
, as provided in the LIRC frequency table, must be added to the t
SST
time in the table
above.
4. The System Speed Switch Time is effectively the time taken for the newly activated oscillator to start up.