1 INTRODUCTION
1.1
Product
Description
The Mongoose LED luminaire has been listed to applicable U.S. &
Canadian safety standards by Underwriters Laboratories Inc. It is
suitable for use in wet locations and ambient temperatures up to 40°C.
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) this device may not cause
harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
•
The LED driver/door assembly can be detached for repair by un-
latching door latches, one cotter pin, and unplugging electrical
connectors.
1.2 Alternate Information Sources.
If additional questions
arise relative to these luminaires that this document or your supplier
cannot answer, please refer them to:
Holophane
Field Service Department
P.O. Box 3004
Newark, OH 43058-3004
(740) 345-9631
2 INSTALLATION
2.1 Tools and Materials Required.
DESCRIPTION
USE
Wrench for 9/16” Hex
Mounting Bolts
Flat-end screwdriver
Terminal Block/Clamp Band
Torque Wrench (ft.-lbs.)
Mounting Bolts
Phillips Head Screw Driver
Photocontrol Adjustment
2.2 Tenon Mounting
2.2.1
Loosen the screw holding the wire chamber cover to the tenon
fitter and remove the cover.
2.2.2
Being careful not to pinch supply wires, slide the fixture onto
the tenon until the tenon seats against the anchor screw. See Figure 1.
Figure 1
GR2119
2.2.3
Align the fixture as necessary and then adjust the appropriate
set screws until the base of the tenon fitter is level.
2.2.4
Tighten the set screws from 10-12 ft-lbs. do not exceed torque.
2.2.5
Make the appropriate electrical connections. If not using a
terminal block use wire rated for at least 75 degree C.
2.2.6
Supply wire connections may be made either in the tenon fitter
wire area or housing. Tenon is standard.
2.2.7
Secure the supply wires with a wire tie in such a way as to
relieve stress on the wire connections.
2.2.8
Replace the wire chamber cover and tighten the screw.
CAUTION
BE CERTAIN THAT NO WIRING IS PINCHED BETWEEN
THE WIRE CHAMBER COVER AND TENON FITTER.
2.2.9
Electrically energize the unit and check for proper operation.
2.3 Horizontal Arm Mounting
2.3.1
Loosen the screw holding the wire chamber cover in place
and remove the cover.
2.3.2
Being careful not to pinch the supply wires, slide the fixture
onto the mounting arm until the seats against the internal stops.
2.3.3
Align the fixture as necessary and then adjust the
appropriate clamp bolts until the fitter is level. See figure 2.
2.3.4
Tighten the clamp bolts for 15-17 ft-lbs.
2.3.5
Follow steps beginning at 2.2.5