1 INTRODUCTION 

 

1.1

 

Product

 

Description

 

The Mongoose LED luminaire has been listed to applicable U.S. & 
Canadian safety standards by Underwriters Laboratories Inc. It is 
suitable for use in wet locations and ambient temperatures up to 40°C. 

This device complies with Part 15 of the FCC Rules. Operation is 
subject to the following two conditions: (1) this device may not cause 
harmful interference, and (2) this device must accept any interference 
received, including interference that may cause undesired operation.

 

 

The LED driver/door assembly can be detached for repair by un-
latching door latches, one cotter pin, and unplugging electrical 
connectors.  

 

1.2  Alternate Information Sources. 

If additional questions 

arise relative to these luminaires that this document or your supplier 
cannot answer, please refer them to: 
 

Holophane 

Field Service Department 

P.O. Box 3004 

Newark, OH  43058-3004 

(740) 345-9631 

 

2 INSTALLATION 

 

2.1  Tools and Materials Required.  

DESCRIPTION  

USE 

Wrench for 9/16” Hex 

 

Mounting Bolts 

Flat-end screwdriver 

 

Terminal Block/Clamp Band 

Torque Wrench (ft.-lbs.) 

 

Mounting Bolts 

Phillips Head Screw Driver 

Photocontrol Adjustment

 

 

 
2.2 Tenon Mounting 
 
2.2.1 

Loosen the screw holding the wire chamber cover to the tenon 

fitter and remove the cover. 

2.2.2 

Being careful not to pinch supply wires, slide the fixture onto 

the tenon until the tenon seats against the anchor screw. See Figure 1. 
 
Figure 1 

 

 

GR2119 

 

2.2.3 

Align the fixture as necessary and then adjust the appropriate 

set screws until the base of the tenon fitter is level. 

2.2.4 

Tighten the set screws from 10-12 ft-lbs. do not exceed torque. 

2.2.5 

Make the appropriate electrical connections.  If not using a 

terminal block use wire rated for at least 75 degree C. 

2.2.6 

Supply wire connections may be made either in the tenon fitter 

wire area or housing.  Tenon is standard. 

2.2.7 

Secure the supply wires with a wire tie in such a way as to 

relieve stress on the wire connections. 

2.2.8 

Replace the wire chamber cover and tighten the screw. 

 

CAUTION 

BE CERTAIN THAT NO WIRING IS PINCHED BETWEEN 
THE WIRE CHAMBER COVER  AND TENON FITTER. 

 

2.2.9 

Electrically energize the unit and check for proper operation. 

 

2.3  Horizontal Arm Mounting 
 
2.3.1 

Loosen the screw holding the wire chamber cover in place 

and remove the cover.

 

2.3.2 

Being careful not to pinch the supply wires, slide the fixture 

onto the mounting arm until the seats against the internal stops.

 

2.3.3 

Align the fixture as necessary and then adjust the 

appropriate clamp bolts until the fitter is level.  See figure 2.

 

2.3.4 

Tighten the clamp bolts for 15-17 ft-lbs.

 

2.3.5 

Follow steps beginning at 2.2.5

 

Отзывы: