background image

Occupancy Sensor LED Luminaire

Cat. No. 9864-LED

DI-000-09864-25A

FOR CANADA ONLY

For warranty information and/or product returns, residents of Canada should contact Leviton in writing at Leviton Manufacturing of Canada Ltd to the attention of the 

Quality Assurance Department, 165 Hymus Blvd, Pointe-Claire (Quebec), Canada H9R 1E9 or by telephone at 1 800 405-5320.

For Technical Assistance Call: 1-800-824-3005 (U.S.A. Only) 1 800 405-5320 (Canada Only) www.leviton.com

LIMITED 2 YEAR WARRANTY AND EXCLUSIONS

Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper 
use for two years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement, at its option. For details visit www.leviton.com or call 1-800-824-3005. This warranty 
excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, 
opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or implied warranties of any kind, including 
merchantability and fitness for a particular purpose
, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a 
particular purpose, is limited to two years. Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, 
lost sales or profits or delay or failure to perform this warranty obligation
. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.

ENGLISH

INSTALLATION INSTRUCTIONS

WARNINGS AND CAUTIONS:

• 

WARNING: 

TO AVOID FIRE SHOCK OR DEATH TURN OFF POWER AT CIRCUIT BREAKER OR FUSE AND TEST THAT POWER IS OFF BEFORE WIRING!

• 

TO BE INSTALLED AND/OR USED IN ACCORDANCE WITH APPROPRIATE ELECTRICAL CODES AND REGULATIONS.

• 

USE THIS DEVICE WITH COPPER OR COPPER CLAD WIRE ONLY.

• 

DO NOT USE WITH DIMMERS, MOTION ACTIVATED CONTROLS OR ILLUMINATED SWITCHES.

• 

FOR INDOOR USE ONLY.

IMPORTANT: Follow these instructions exactly to maintain polarity of a correctly wired system. NOTE: Supply conductors must have minimum 90° C rating.

WARNING: 

TO AVOID FIRE SHOCK OR DEATH TURN OFF POWER AT CIRCUIT BREAKER OR FUSE AND TEST THAT POWER IS OFF BEFORE WIRING!

1. Remove bezel for mounting by turning counter clockwise until tick marks do not line up (Fig. 1)

NOTE: When mounting on 3-1/4" (8.25 cm) standard outlet box, use inner mounting holes on base of luminaire. When mounting on a 4" (10.16 cm) box, use outer 

mounting holes on base of luminaire (Fig. 2)NOTE: Product incorporates 4 mounting holes to position for maximum coverage. Sensor should face entrance (Fig. 3).

2. Partially screw in two long mounting screws provided into outlet box.

3. Strip insulation off end of each circuit wire to expose 3/4" (1.9 cm) bare copper. If stranded wire is used, twist wire to prevent loose strands.

4. CONNECT WIRES AS FOLLOWS: BLACK luminaire lead to outlet box LINE (Hot), WHITE luminaire lead to outlet box NEUTRAL, GREEN luminaire lead to outlet box

GROUND.

5. Positioning - Mount luminaire to box with the occupancy sensor lens facing the entrance (Fig. 3). Mount the luminaire base on outlet box by placing over mounting screws 

and rotating (clockwise for 4" box, counter clockwise for 3-1/4" box). Tighten mounting screws. If using power tools, ensure power tool is set to low impact.

6. Install bezel by pushing in and twisting clockwise until tick marks line up and it locks into place.

7. Restore power at circuit breaker or fuse. Installation is complete.

NOTE: LED Indicator is blinking ON/OFF when motion is detected. When no motion is detected, LED Indicator will stop blinking and luminaire will turn OFF 

after three minutes.

INSTALLATION

LED Consumption:  8.7 Watts

Light Output: 

800 Lumens

Lamp Color: 

4000 K

SPECIFICATIONS

FCC COMPLIANCE

This device complies with part 15 of the FCC Rules. Operation is subject to the 

following two conditions: (1) This device may not cause harmful interference, and (2) 

this device must accept any interference received, including interference that may 

cause undesired operation.

INDUSTRY CANADA COMPLIANCE

This device complies with Industry Canada license-exempt RSS standard(s). 

Operation is subject to the following two conditions: (1) this device may not cause 

interference, and (2) this device must accept any interference, including interference 

that may cause undesired operation of the device.

FIG. 1

FIG. 2

FIG. 3

Sensor

facing entrance

Détecteur orienté

vers l’entrée

Sensor hacia

la entrada

Line 120VAC, 60 Hz

Ligne 120 V c.a., 60 Hz

Línea 120VCA, 60 Hz

Hot (Black)

Actif (noir)

Fase (Negro)

Green Ground

Terre vert

Verde a Tierra

Neutral (White)

Neutre (blanc)

Neutro (Blanco)

Mounting Hole

for 3-1/4" box

Trou pour une

boîte de 3 1/4 po

Orificio de

montaje

para caja

de 3-1/4" 

Mounting Hole

for 4" box

Trou pour une

boîte de 4 po

Orificio de

montaje

para caja

de 4" 

Bezel

Lunette

Bisel

LED

Lamp

Cover

Couvercle

de la lampe

à DEL

Cubierta de la

lámpara LED

Sensor

Détecteur

Sensor

LED

Indicator

Témoin

Indicador LED

Отзывы: