27
a
Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile
radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To
assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered.
If the measured field strength in the location in which the ATEC Sapphire Console is used exceeds the applicable
RF compliance level above, the ATEC Sapphire Console should be observed to verify normal operation. If abnormal
performance is observed, additional measures may be necessary, such as re-orienting or relocating the ATEC Sapphire
Console.
b
Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m.
TABLE 8: RECOMMENDED SEPARATION DISTANCES BETWEEN PORTABLE AND MOBILE RF COMMUNICATIONS
EQUIPMENT AND THE ATEC SAPPHIRE CONSOLE
The ATEC Sapphire Console is intended for use in the electromagnetic environment in which radiated RF disturbances
are controlled. The customer or the user of the ATEC Sapphire Console can help prevent electromagnetic interference by
maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the ATEC
Sapphire Console as recommended in the following table, according to the maximum output power of the communications
device.
Rated maximum output
power of transmitter
(W)
Separation distance according to frequency of transmitter
(m)
150 kHz to 80 MHz
d=1.2√P
80 MHz to 800 MHz
d=1.2√P
800 MHz to 2.5 GHz
d=1.2√P
0.01
0.12
0.12
0.23
0.1
0.37
0.37
0.74
1
1.2
1.2
2.3
10
3.7
3.7
7.4
100
12
12
23
For transmitters rated at a maximum output power not listed above, the recommended separation distance d in meters (m)
can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power
rating of the transmitter in watts (W) according to the transmitter manufacturer.
NOTE 1:
At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.
NOTE 2:
These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and
reflection from structures, objects and people.
Classification
Type of protection against electric shock: Class I
Degree of protection against electric shock: Type BF
Degree of protection against the ingress of water: Ordinary
Mode of Operation: Continuous
Disposal
Equipment to be disposed in compliance with European Directive 2002/96/EC on Waste Electrical and Electronic
Equipment (WEEE).
More Information
For product availability, or other information, contact your Hologic Representative or call Customer Support toll free at
877-887-8767. If you are an international customer, please contact your distributor for more information. To report a quality
issue, contact the Quality line at 888-355-7876 option 1.
Содержание ATEC SAPPHIRE
Страница 35: ...35...
Страница 36: ...36 Hologic Inc 250 Campus Drive Marlborough MA 01752 USA www hologic com 877 887 8767...