EN
PCT50
916.400.139_002
51
6.4.4
Cleaning and storage
After normal use
1. Clean the tool and any accessories before storage.
2. Dry the tool if it was used in wet conditions. Apply a thin coat of preservative oil to the external steel
parts.
3. Store the tool in a dry and well-ventilated area.
After immersion
If a Holmatro Certified Technician can not clean the tool within 1 week, do these temporary maintenance
steps that follow. The Holmatro Certified Technician must clean the tool subsequently.
1. Remove the battery pack. Flush the tool, battery pack and accessories with fresh, clean water.
2. If the tool has been used in muddy or dirty water, the c
overs
must be removed to remove residual
dirt.
Refer to Fig. 17
i
Remove the screws (A, 8x) from the upper c
over
.
ii
Remove the upper c
over
(B). Do not disconnect wiring.
iii
Remove the crews (C, 6x) from the bottom c
over
s.
iv
Remove the bottom c
over
s (D, 2x).
3. Flush the inner parts with fresh clean water and remove residual dirt and contamination.
4. Lubricate all exposed steel parts with a rust inhibitor and moisture repellant.
5. Let the tool, battery and accessories dry in the air at room temperature.
6. Install the c
over
s.
7. Store the tool in a dry and well-ventilated area.
Additional steps if the tool does not respond to the control handle after immersion.
If the motor keeps running, clean the control sensors inside the control handle.
1. Refer to Fig. 18
i
The upper c
over
must be removed (A, 8x) (B). Do not disconnect wiring.
ii
Remove the crews from the control handle ring (C, 5x).
iii
Remove the control handle ring (D). Do not disconnect wiring.
iv
Open the dust cap (E).
v
Remove the lock ring (F).
vi
Remove the control handle (G).
2. Flush the control sensors (H, 2x) with fresh clean water and remove remaining dirt and
contamination.
3. Lubricate all exposed steel parts with a rust inhibitor and moisture repellant.
4. Let the tool dry in the air at room temperature.
5. Install the parts.
6. Store the tool in a dry and well-ventilated area.
NOTICE
If the tool has been used under water, a Holmatro Certified Technician must clean the tool as
soon as possible. To make sure that the tool operates correctly, it must be cleaned in less
than 1 week.
Содержание PCT50
Страница 1: ...i PCT50 Handleiding NL Manual EN Mode d emploi FR Betriebsanleitung DE Manual ES Manual PT ZH...
Страница 3: ...PCT50 916 400 139_002 3 Fig 1 Fig 2...
Страница 4: ...4 916 400 139_002 PCT50 Fig 3 Fig 4 Fig 5 Fig 6 Fig 7 Fig 8...
Страница 168: ...ZH 168 916 400 139_002 PCT50 1 1 1 1 2 1 3 i 1 4 1 5 Pentheon 1 5 1 1 6 1 7...
Страница 169: ...ZH PCT50 916 400 139_002 169 1 8 CE 2 2 1 2 2 Fig 1...
Страница 170: ...ZH 170 916 400 139_002 PCT50 i Pos A CE B 921 000 084...
Страница 171: ...ZH PCT50 916 400 139_002 171 2 3 2 4 2 5 Fig 12...
Страница 172: ...ZH 172 916 400 139_002 PCT50 2 6 2 7 2 8 5 2 30 1 40 C 104 F...
Страница 173: ...ZH PCT50 916 400 139_002 173 3 Fig 5 2 9 2 10 EN ISO 12100 2 11...
Страница 180: ...ZH 180 916 400 139_002 PCT50 4 4 1 5 2 5 5 1 5 2 18 C 24 C 64 F 75 F SOC 5 3 Fig 10 5 4 Fig 5 100 24 24...
Страница 181: ...ZH PCT50 916 400 139_002 181 5 5 on off LED LED LED 5 6 i 5 7 LED LED 6 6 1 10 on off LED...
Страница 182: ...ZH 182 916 400 139_002 PCT50 6 2 3 6 2 6 3 6 3 1 LED on off Fig 9 Fig 10 on off 6 3 2 6 3 3 Fig 11 Fig 12 45 C 113 F...
Страница 183: ...ZH PCT50 916 400 139_002 183 Fig 8 A B C 6 3 4 25mm 6 3 5 25mm Fig 13...
Страница 184: ...ZH 184 916 400 139_002 PCT50 6 3 6 6 3 7 3 4 2 6 3 8 6 4 6 4 1 3 6 2 6 4 2 3 10 2...
Страница 187: ...ZH PCT50 916 400 139_002 187 7 7 i 8 8 1 8 2 8 3 i 8 4 i 6 4 4 WD 40 Valvoline Tectyl ML 10 3 25 100 x x x...
Страница 190: ...ZH 190 916 400 139_002 PCT50 45 C 113 F 9 Fig 14 NBR 3 WEEE 2012 19 EU RoHS 2011 65 EU...
Страница 191: ...191 916 400 139_002 i Fig 9 Fig 10...
Страница 192: ...192 916 400 139_002 PCT50 i Fig 11 Fig 12 Fig 13 Fig 14 90...
Страница 194: ...194 916 400 139_002 PCT50 i Fig 17 Fig 18...