B U L L E T I N
G L V - 4 0 S 1 # 1 1 9 6 G E A R L E S S T R A C T I O N M A C H I N E
Page 5-6
Rev. A - 04/01/2022
3. Rotate installing bolts clockwise, fix the brake and the machine base, making sure the
gap is
between 0.012” (0.30 mm) to 0.022” (0.55 mm).
4. Rotate 4 guide screws clockwise, making sure they seat firmly on the base installing
surface. Figure 11.
Check the air gap of the brake, it should be within
0.012” (0.30 mm) to 0.022” (0.55 mm).
When the air gap of brake is less than 0.012
” (0.3 mm) please do as follows:
1.
Rotate 4 installing bolts counterclockwise until the 0.012” (0.30 mm) to 0.022” (0.55
mm) feeler gauge can be put in.
2. Rotate 4 guide screws clockwise, making sure they seat firmly on the base installing
surface. Figure 11.
3.
Tighten 4 installing bolts clockwise until the 0.012” (0.30 mm) to 0.022” (0.55 mm) feeler
can be put out freely.
Check the air gap of the brake, it should be within 0.012” (0.30 mm) to 0.022” (0.55 mm).
21mm
WRENCH
GUIDE
SCREW
Figure 11