B U L L E T I N
G L V - 4 0 S 1 # 1 1 9 6 G E A R L E S S T R A C T I O N M A C H I N E
Page 4-4
Rev. A - 04/01/2022
Brake Specification
•
Four brakes are supplied standard from the factory. Two brakes are meant to serve as
a primary machine brake and the other two brakes as a secondary emergency brake.
Please contact Hollister-Whitney for details regarding using a Rope Gripper
®
as the
emergency brake with a GLV-40S1 machine.
•
Brake switch rating DC 110 V Rated current 1.98 A.
•
The opening voltage of the brake is not more than 110 V, the releasing voltage is not
more than 70 V, and the control range is 15 V-30 V.
•
The machine brakes are mounted in 4 locations as shown in Figure 4.
Figure 4
BRAKE