B U L L E T I N # 1 1 9 4 G L V - 4 0 D 1 G E A R L E S S T R A C T I O N M A C H I N E
Page 4-4
Rev. A - 04/01/2022
Brake Specifications
•
Four brakes are supplied standard from the factory. Two brakes are meant to serve as
a primary machine brake and the other two brakes as a secondary emergency brake.
Please contact Hollister-Whitney for details regarding using a Rope Gripper
®
as the
emergency brake with a GLV-40D1 machine.
•
Brake switch rating DC 110 V Rated current 1.98 A.
•
The opening voltage of the brake is not more than 110 V, the releasing voltage is not
more than 70 V, and the control range is 15 V-30 V.
•
The machine brakes are mounted in 4 locations as shown in Figure 4.
Figure 4
BRAKE
LOCATION #1
BRAKE
LOCATION #4
BRAKE
LOCATION #2
BRAKE
LOCATION #3
Содержание GLV-40D1 Series
Страница 37: ...B U L L E T I N 1 1 9 4 G L V 4 0 D 1 G E A R L E S S T R A C T I O N M A C H I N E Page 8 2 Rev A 04 01 2022 ...
Страница 38: ...B U L L E T I N 1 1 9 4 G L V 4 0 D 1 G E A R L E S S T R A C T I O N M A C H I N E Page 8 3 Rev A 04 01 2022 ...
Страница 39: ...Page 9 1 Rev A 04 01 2022 Notes Section 9 ...