HLP-A Series
HLP-A Series
-
25
-
2) Description of Display Items
5. Description of Operation Examples
Procedures
Display
Indicator
Lamp
Explanation
Power up
↓
←
Dsp2.0
AXX.XX
FWD Hz
¢ ¤
Self detect when power-up,
display version no. display
running f requency
PROG
↓
CD000
FWD Hz
¢ ¤
Enter programming
Display the f unction of CD000
ENTER
↓
000.00
FWD Hz
¢ ¤
Display the content of CD000
←▲
ENTER
↓
PROG
50.00
END
CD001
50.00(flash)
FWD Hz
¢ ¤
FWD Hz
¢ ¤
Change the content of CD000
Confirm changed value
Display END→CD001
Black f rom programming
↓
RUN
00.00→ 50.00
FWD Hz
¤ ¤ Display running and operating f requency
↓
DISP
50.00
FWD Hz
¤ ¤ Display running and operating f requency
↓
DISP
005.0
FWD A
¤ ¤
Monitor screen switching, display output
current
↓
DISP
01440
FWD r/min
¤ ¤
Monitor screen switching, display rotate speed