background image

1

2

3

4

5

6

7

8

A

B

C

D

8

7

6

5

4

3

2

1

D

C

B

A

P33

1

P34

2

P35

3

P36

4

P37

5

P40

9

P41

10

P42

11

P43

12

P44

13

P45

14

P46

15

P47

16

TEST

20

RESET

24

XIN

18

XOUT

19

VSS

17

VAREF

6

P22

23

P20

25

P00/INT0

26

P01

27

P02

28

P03

29

P04

30

P05

31

P06

32

P07

33

P15

34

P14

35

P13

36

P12

37

P11

38

P10

39

P30

40

P31

41

VDD

21

AVSS

8

AVDD

7

P21

22

P32

42

IC1

TMP86PM46N

ÍÂÆø

±¸ÓÃζÈ

ѹ»ú¿ÇÌåζÈ

ÉÏÉý/Ͻµ

·§/·ç»ú

»·¾³

³ý˪

ÎüÆø

·ç»úµ÷ËÙ

·çËÙ·´À¡

Ç¿ÖÆÖÆÀä

Ç¿ÖÆÖÆÈÈ

SERIAL

SS/TEST

±¸ÓÃ

±¸ÓÃ

TOÊÒÄÚ»ú

FROMÊÒÄÚ»ú

±¸ÓÃ

FROMÄ£¿é

TOÄ£¿é

ÅòÕÍ·§D

ÅòÕÍ·§C

ÅòÕÍ·§B

ÅòÕÍ·§A

ËÄͨ

¸ß/µÍ·ç

·ç»ú¿ª¹Ø

Ñõ°É

PTC

±¸Óü̵çÆ÷

SCL

SDA/ERR_LED

C17

30P

C18

30P

X1

16.000MHz

R13

10K

1

2

3

IC9

PST600D

+5V

1

2

3

4

5

6

7

GND

8

COM

9

10

11

12

13

14

15

16

COM

IC2

ULN2003

1

2

3

4

5 6

CN2

XC25-06WS

A

+12V

B

C

D

CD1

25V/220U

1
2
3
4

CN3

B4B-XH-A

+12V

RX

TX

GND

Q1

S9013

R1

560

C1

1000P

R2

22K

+5V

R3

1K

C2

1000P

R11

10K

+12V

R16

10K

+5V

IC5

TLP371

IC6

TLP521

C3 1000P

R12

10K

+5V

R36

390

C4

1000P

R25

330

D1

1N4007

R4

1K

R30

15K

R29

15K

R28

15K

D2

1N4007

R31

22K/2W

D3

1N4007

FU1

275V-25A

CD3

22uF/250V

R33

220K

R34

220K

R35

220K

D4

1N4007

C7

275V-103

L1

T10022

C13

275-474

C15

275-472

C16

275-472

ZE1

S14K350

SA1

RA-362M

1

CN6

KET6.3

1

CN7

KET6.3

220VAC-L

220VAC-N

L3

059

L2

T10022

C14

275-474

ZE2

S14K350

C12

275-474

PTC1

PTC

1

CN9

KET6.3

1

CN5

KET6.3

RL1

G4A-1A

RL2

PCH-112D2H/G5S-1

RL3

OJE-SS-112DM

RL4

OJE-SS-112DM

1

2 3

CN14

B2P3-VH

四通

C9

275V-103

R53

100/1W

1

2

3

CN15

B2P3-VH

单速风机

(

备用

)

1

2

3 4

5

CN18

B3P5-VH

C29

CBB61-1.5UF-500V

H

L

COM

+15VB

1

2

3

4

5

6

7

GND

8

COM

9 10

11

12

13

14

15

16

COM

IC3

ULN2003

RL6

OJE-SS-112DM

1

2

3

CN17

B2P3-VH

C11

275V-103

R55

100/1W

备用

1

2
3

CN19

B3B-XH-A(

)

1
2
3

CN20

B3B-XH-A(

)

1
2
3

CN22

B3B-XH-A(

)

1
2

CN21

B2B-XH-A(

绿

)

Ta

Te

Td

Ts

CD9

50V/4.7U

CD10

50V/4.7U

CD11

50V/4.7U

CD12

50V/4.7U

+5V

R7

1K

R6

1K

R5

1K

R8

1K

R9

1K

1
2
3

CN23

B3B-XH-A(

)

备用

CD13

50V/4.7U

R15

10K

R14

10K

+5V

CJ1

TJC8-02A

+5V

1

2

CN11

B2B-XH-A

R40

2K

R41

2K

R39

2K

C23

103

+5V

R43

2K

R44

2K

R42

2K

C24

103

+5V

R38

100K

R37

100K

C22

103

R10

1K

+5V

R21

10K

1

2

CN12

B2B-XH-A

1

2

CN13

B2B-XH-A

A0

1

A1

2

A2

3

GND

4

SDA

5

SCL

6

WP

7

VCC

8

IC12

AT24C02

R23

10K

R24

10K

R22

10K

C21

104

+5V

ALARM

SL-342VR

R47

330

+5V

CD1

400V/680U

CD2

400V/680U

CD3

400V/680U

1

CN3

KET6.3

1

CN4

KET6.3

CD2

25V/220U

C30

275-104

D5

RS1J

C8

275V-103

D6

RS1J

D8

4148

C25

103

CD15

25V-10UF

CD16

50V-1UF

R58

1

R59

1

Q2

2SC2712

R60

5.1K

ZD1

12V/0.5W

R61

1.5K

R62

27

CD8

25V-470UF

+15VB

D7

RS1J

CD17

25V-220UF

+15VA

9

10

6

7

1

3

4

5

T1

E22012

GND1

BUS+

DRAIN

VCC

Softst

FB

Isense

GND

NC

1

2

3

8

6

5

4

7

IC10

ICE2A265

C20

104

R56

1M

R57

1M

R46

160K

R45

160K

+310V

0V

1

2

3

4

5

6

CN24

B6P6-VH

BUS+

GND1

+310V

0V

电源
调速

速度反馈

IC8

TLP521

IC7

TLP521

R64

330

ZD2

5.1V/0.5W

R63

330

GND1

+15VA

R65

330

+5V

R66

1K

ZD3

9V/0.5W

R67

1K

R68

2K

CD14

50V/4.7U

C26

103

R69

1K

7805

IC11

7805

CD19

16V-100UF

+5V

CD18

25V-220UF

+12V

SW1

H=5

SW2

H=5

SW3

H=5

SW4

H=5

CJ2

TJC8-02A

CJ3

TJC8-02A

C19

104

R48

20K

R49

47K

R50

20K

R51

20K

R52

20K

J16

10MM

+12V

J7

10MM

15V

15V

15V

SS

SERIAL

COOL

HEAT

壳体保护

压力开关

UP

DOWN

FA

FAN

J42

10MM

R70

10K

1
2
3
4

5

RP2

10K*4

+5V

R1

220K

R2

220K

µçÈݰ岿·Ö

CP1

1000PF*8

LED1

SL-342VR

R17

110K-2W

1
2
3
4
5

6

RP2

10K*5

1

CN10

KET6.3

1

CN10'

KET6.3

大地

内机通讯

(

)

(

)

(

)

火线出

(

)

零线出

*J23

10MM

SPDU

模块通讯

环温

除霜

吐气

吸气

*R18

10K

直流外风机

PMV

两速风机

 

Classic Line Air Conditioner  

       

    

Model: HKEN-HCNN 642 XR 

   

 

 
 
 
 
 
 
 
 
 

 

 
 

 

Содержание HKEN-HCNN 642XR

Страница 1: ...Classic Line Air Conditioner SERVICE MANUAL Model HKEN HCNN 642XR l Features l Comfortable wide angle airflow l Health air purifying l Quiet operation l Energy efficient ...

Страница 2: ...CONTENT Classic Line Air Conditioner Model HKEN HCNN 642 XR ...

Страница 3: ...SERIES INTRODUCTION Classic Line Air Conditioner Model HKEN HCNN 642 XR ...

Страница 4: ...ctions 5 Convenience Auto restart and washable panel The grille can be removed easily and washed when necessary Any series have the function then even if the power falls when the unit is operating unit will automatically return to the operating settings in use before the power failure when power is restored 6 Wide variety of functions 24 Hour Timer 24 hour timer allows users to select the exact ti...

Страница 5: ...SPECIFICATIONS Classic Line Air Conditioner Model HKEN HCNN 642 XR ...

Страница 6: ...nit 949 x 745 x 406 Net gross weight kg indoor unit 12 15 Net gross weight kg outdoor unit 45 53 Max mounting height indoor unit 8 difference m 10 Piling layers outdoor unit 4 1900 Current entering side indoor outdoor Outdoor Refrigerant charge g R410A Frequency of filter cleaning Once 2 weeks Max refrigerant charge g 15 Compressor model C 6RVN93H0N Compressor manufacturer HUARUN Compressor oil ch...

Страница 7: ...CURVES OF PERFORMANCE OF COMPRESSOR Classic Line Air Conditioner Model HKEN HCNN 642 XR ...

Страница 8: ...150 90 100 110 120 130 140 Curves of cooling capacity and heating capacity as a function of outdoor temperature 7O C 43O C 15 20 25 15 20 25 Classic Line Air Conditioner Model HKEN HCNN 642 XR ...

Страница 9: ...DESCRIPTION DIMENSION AND FUNCTION OF MAIN COMPONENTS AND ACCESSORIES Classic Line Air Conditioner Model HKEN HCNN 642 XR ...

Страница 10: ...ights up when unit starts Lights up when Timer operation is selected Lights up during compressor running A beeping sound is generated when a signal from remote controller is received Used when remote controller is lost or defective Unit will run temporarily Used only for test running in cooling when room temp is below 16o C Don t use it in normal operation For model HKEN 642 XR Classic Line Air Co...

Страница 11: ...938 265 Indoor unit for HKEN 642 XR NET DIMENSIONS 182 NET DIMENSIONS Outdoor unit for HCNN 642 XR 583 113 5 690 810 Classic Line Air Conditioner Model HKEN HCNN 642 XR ...

Страница 12: ...KNOCK DOWN DRAWINGS Classic Line Air Conditioner Model HKEN HCNN 642 XR ...

Страница 13: ...Model HSU 18H03 R2 DB Classic Line Air Conditioner Model HKEN HCNN 642 XR ...

Страница 14: ...3 4 5 2 2 6 7 8 9 11 10 1 2 13 1 1 2 14 5 1 17 6 1 1 8 9 2 2 2 1 2 3 4 2 5 2 6 0 KNOCK DOWN DRAWINGS FOR OUTDOOR UNIT Classic Line Air Conditioner Model HKEN HCNN 642 XR ...

Страница 15: ...BRIEF INTRODUCTION TO ELECTRICAL CONTROL FUNCTIONS Classic Line Air Conditioner Model HKEN HCNN 642 XR ...

Страница 16: ...perature cooling mode 4 Compressor On Compressor is on when indoor temperature is 0 67o below set temperature heating mode 0 67o above set temperature cooling mode 5 Remote Control Operation In remote control if temperature changes PI operation will start in 2s If change of set temperature is towards compressor off compressor will shut down when it falls into compressor off temperature range 6 Ind...

Страница 17: ...rature rises into compressor off temperature range 15 minutes after compressor is off compressor will perform temperature check at which time if Tr Ts 3 the system will enter cooling mode otherwise it will remain in heating mode 2 Cooling Mode Temperature Control Range 16 30 Temperature Difference 1 In the first 2 minutes after compressor starts it is not under the control of temperature sensor Co...

Страница 18: ...of unit shut down or unit is powered off manually the operation is not restricted by the 2 minute non response feature and will shut down immediately 4 Heating Mode Temperature Control Range 16 30 Temperature Difference 1 Control Feature When for the first time Tr Ts compressor four way valve and external fan are turned on and indoor fan operates at anti cold wind mode 4o temperature compensation ...

Страница 19: ...ctor will close after set wind blows for 1 minute Automatic Temperature Compensation in Heating Mode 1 Condition Compressor shutdown time is less than 5 minutes 2 Operation Rule 1 Ts Trc 5 Trc Tt The instant when compressor starts up 2 Trc Tt The instant when compressor starts up 2 Note The above two conditions are not applicable to initial start up 3 Press temperature key on remote control and re...

Страница 20: ... low load protection will not be activated 10 EEPROM Control When outdoor unit is supplied with power if EEPROM parameter is inconsistent with checksum EEPROM faults When indoor unit receives EEPROM fault signal from outdoor unit it will display outdoor unit EEPROM fault At this time control and emergency operation are not accepted and the fault can only be relieved by power off Three Special Func...

Страница 21: ...gency Switch When unit is in shutdown condition press emergency switch down for less than 5s the unit will start emergency operation When unit is in shutdown condition press emergency switch down for more than 5s but less than 10s the unit will start trial operation When shutdown press emergency switch down for more than 10s but less than 15s it will display the previous fault When unit is in shut...

Страница 22: ...ncy will be compensated as per relevant conditions 1 1 4 Cooling Dehumidification z When completing compressor startup operation it will operate as per frequency of indoor unit z After 2 minutes compressor operation frequency will be compensated as per relevant conditions 1 1 5 Compressor Frequency Increase Decrease Speed Rapid Frequency Increase Decrease Speed 1 1HZ s Slow Frequency Increase Decr...

Страница 23: ...ue is set at 6 when unit leaves the factory Defrosting entry temperature control 15 C TA α 5 B Defrosting Time Interval z When data calculated by C TA αfalls into the range of 15 C TA α time interval between two defrosting cycles is 45 minutes z When data calculated by C TA αfalls into the range of C TA α 15 time interval between two defrosting cycles is 65 minutes z C Defrosting Operation z When ...

Страница 24: ...down and initial energization valves are turned on to adequate opening position after being fully turned off 2 2 TD High Temperature Protection As long as unit is on the TD air discharge overheat protection feature will be activated yet air discharge sensor fault must be alarmed 4 minutes after compressor starts TD Abnormal Shutdown 117 rapid frequency drop 1HZ s 109 slow frequency drop 1HZ 10s 98...

Страница 25: ...cy will rise at a speed of 1HZ 10s If TC 0 for 2 consecutive minutes compressor will shutdown and outdoor fault lamp blinks Fault will not be reported to indoor unit When compressor shuts down for more than 3 minutes and when TC 7 compressor will restart 2 6 Outdoor Temperature Limit Cooling When outdoor temperature is lower than 15 cooling operation will start compressor frequency is limited to l...

Страница 26: ...EPROM and all the protection features are effective Three Fault Display and Treatment z In case outdoor unit faults the alarm indicator lamp will blink and blink frequency is 1HZ Time interval between blink cycles is 3s z Alarm indicator lamp is off when there is no fault z Three are three ways of fault alarm It is ensured that fault alarm indicator lamp will blink for more than 2 minutes and 30s ...

Страница 27: ...WIRING DIAGRAM Classic Line Air Conditioner Model HKEN HCNN 642 XR ...

Страница 28: ...Classic Line Air Conditioner Model HKEN HCNN 642 XR ...

Страница 29: ...LOCK FILTER FUSE T25A 250VAC TO INDOOR POWER SUPPLY R RED Y G YELLOW GREEN BL BLUE OR ORANGE W WHITE Y YELLOW B BLACK CAUTION The capacitor retains high voltage even after the plug off For your safety be sure to wait at least 5 minutes after plug off and use a tester to confirm the voltage between connector CN3 and CN4 is less than DC 10V before start servicing DON T TOUCH CAPACITOR EVEN AFTER PLU...

Страница 30: ...CIRCUIT DIAGRAM Classic Line Air Conditioner Model HKEN HCNN 642 XR ...

Страница 31: ...102 1 2 3 4 5 6 7 8 5V C11 104 IC2 IC3 IC1 5V TIMER RUN GND 5V REC 1 2 3 4 CN4 5V R13 3 3K R14 20K C12 102 C13 102 ROOM PIPE R15 10K 风机输出 面板选择 导板选择 室外通讯输入 A B C D 蜂鸣器 TXO TXI FLZ PGO C1 102 C2 103 C5 103 C9 103 R32 1K E8 4 7U R19 10K R18 10K R20 1K Q3 9013 R17 10K E4 470uF 16V C15 104 Vout 3 GND 2 Vin 1 IC4 7805 FUSE1 T3 15A 250VAC C20 1uF 275VAC 1 2 3 4 IN4007 ZE1 S14K350 E3 1000uF 35V C14 104 5V...

Страница 32: ...OM IC3 ULN2003 RL6 OJE SS 112DM 1 2 3 CN17 B2P3 VH C11 275V 103 R55 100 1W 备用 1 2 3 CN19 B3B XH A 蓝 1 2 3 CN20 B3B XH A 白 1 2 3 CN22 B3B XH A 黄 1 2 CN21 B2B XH A 绿 Ta Te Td Ts CD9 50V 4 7U CD10 50V 4 7U CD11 50V 4 7U CD12 50V 4 7U 5V R7 1K R6 1K R5 1K R8 1K R9 1K 1 2 3 CN23 B3B XH A 红 备用 CD13 50V 4 7U R15 10K R14 10K 5V CJ1 TJC8 02A 5V 1 2 CN11 B2B XH A R40 2K R41 2K R39 2K C23 103 5V R43 2K R44 2...

Страница 33: ...ABNORMITY DIAGNOSE Classic Line Air Conditioner Model HKEN HCNN 642 XR ...

Страница 34: ...k once The sames cycle goes on Fault codes Faulty Points Power Timing Running Indoor Outdoor Resumable Faulty indoor thermistor Blinking Off Off Sensor in short or broken current Faulty indoor thermistor Blinking On On Sensor in short or broken current Faulty EEPROM Blinking On Blinking Wrong data or no EEPROM Defrosting temperature sensor in short or broken current On On Blinking Poor contact of ...

Страница 35: ...ermistor fault Outdoor air intake thermistor fault Compressor suction temperature too high Compressor startup fault Compressor rotor out of position compressor out of synchronism Rotor position sensing circuit fault Flashing times of O U LED 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 Outdoor air thermistor fault Outdoor unit discharge thermistor fault Communication is abnormal between indoor and ou...

Страница 36: ...TROUBLE SHOOTING Classic Line Air Conditioner Model HKEN HCNN 642 XR ...

Страница 37: ...Classic Line Air Conditioner Model HKEN HCNN 642 XR ...

Страница 38: ...REFRIGERATING CYCLE DIAGRAM Classic Line Air Conditioner Model HKEN HCNN 642 XR ...

Страница 39: ...Classic Line Air Conditioner Model HKEN HCNN 642 XR ...

Страница 40: ...NOISE LEVEL TEST CHART AND AIR VELOCITY DISTRIBUTION Classic Line Air Conditioner Model HKEN HCNN 642 XR ...

Страница 41: ...elocity distribution Noise level test chart 0 10 20 30 40 50 60 63Hz 125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz 8000Hz 0 10 20 30 40 50 60 dB A indoor outdoor MODEL HKEN HCNN 642 XR dB A Classic Line Air Conditioner Model HKEN HCNN 642 XR ...

Страница 42: ...anel vertical lourer center Condition Fan speed high Operation mode fan Voltage 230V 50Hz Fig 2 top view flow control panel horizal lourer right and left Air velocity distribution 10 9 8 7 6 5 4 3 2 1 1 1 2 2 0 m 0 25 0 5 1 0 2 0 m 10 9 8 7 6 5 4 3 2 1 0 3 1 8 1 0 25 unitm s m 0 1 2 3 4 5 6 0 5 m 1 0 2 0 3 0 1 8 3 m 10 9 8 7 6 5 4 3 2 1 0 m3 2 0 1 2 1 2 0 1 0 0 5 0 25 1 0 0 5 0 25 unit m s unit m ...

Страница 43: ...INSTALLATION MANUAL Classic Line Air Conditioner Model HKEN HCNN 642 XR ...

Страница 44: ...e L S with screws Connecting electric cable for indoor and outdoor Drain hose Heating insulating material Piping hole cover No Accessory parts Remote controller R 03 dry battery Mounting plate Drain hose Steel nail cement Screw Plastic cap Drain elbow Cover Cushion 1 1 2 3 4 5 6 7 8 9 10 2 1 1 6 4 1 1 4 1 Number of articles Accessory parts 4X50 4X25 Pipe supporting plate Arrangement of piping dire...

Страница 45: ... a wall place where the indoor unit can receive signals when the fluorescent lamps in the room are lightened Place which is less affected by rain or direct sunlight and is sufficiently ventilated Place possible to bear the unit where vibration and noise are not increased Place where discharged wind and noise do not cause a nuisance to the neighbors Place where a distance marked is available as ill...

Страница 46: ... installation Section of wall hole Piping hole pipe Outdoor side Thickness of wall Indoor side Wall hole 60mm Indoor unit 1 Fitting of the Mounting Plate and Positioning of the wall Hole When the mounting plate is first fixed 1 Carry out based on the neighboring pillars or lintels a proper leveling for the plate to be fixed against the wall then temporarily fasten the plate with one steel nail 2 M...

Страница 47: ...ive tape Other direction piping Indoor outdoor electric cable and drain hose must be bound with refrigerant piping by protecting tape Cut away with a nipper the lid for piping according to the piping direction and then bend the pipe according to the position of wall hole When bending be careful not to crash pipes Connect beforehand the indoor outdoor electric cable and then pull out the connected ...

Страница 48: ...ure the cables have been properly inserted and tightened After the cable connection never fail to fasten the connected cable with the wiring cover Note When connecting the cable confirm the terminal number of indoor and outdoor units carefully If wiring is not correct proper operation can not be carried out and will cause defect 1 If the supply cord is damaged it must be replaced by the manufactur...

Страница 49: ...t is over 5m the function of the unit will be affected If the pipe has to be lengthened the refrigerant should be charged according to 20 g m But the charge of refrigerant must be conducted by professional air conditioner engineer Before adding additional refrigerant perform air purging from the refrigerant pipes and indoor unit using a vacuum pump then charge additional refrigerant 3 Connection U...

Страница 50: ...open 2 way valve and 3 way Turn the valve rod anticlockwise until hitting lightly To prevent the gas leakage turn the service port s cap the valve rod s cap for 2 way valve and 3 way s a little more than the point where the torque increases suddenly After attaching the each caps check the gas leakage around the caps CAUTION 1 If the refrigerant of the air conditioner leaks it is necessary to disch...

Страница 51: ... the drain hose so as to be downward slope without fail Please don t do the drainage as shown below Please pour water in the drain pan of the indoor unit and confirm that drainage is carried out surely to outdoor In case that the attached drain hose is in a room please apply heat insulation to it without fail Please kindly explain to our customers how to operate through the instruction manual Gas ...

Страница 52: ...Bologna Italy Tel 39 051 41 33 111 Fax 39 051 41 33 112 www termalgroup com Due to on going technological development of the products by the manufacturer we reserve the right to vary the technical specifications at any time without notice ...

Отзывы: