Service manual
10. Troubleshooting
10.1 Display board
Operation
The indicator flashes once every second after power is on and illuminates when the air conditioner is in
operation.
Timer indicator:
The indicator illuminates then TIMER is set ON.
PRE-DEF. indicator (For cooling & heating mode only)
The air conditioner starts defrosting automatically if outdoor unit frosts in heating operating.
At this time, PRE-DEF. indicator illuminates.
Auto indicator:
This indicator flashes when the air conditioner is in AUTO operation.
ECON indicator
This indicator illuminates while the air conditioner is in economic operation.
10.2 Troubleshooting
For cooling mode:
Failure phenomenon
Operation
lamp
Timer
lamp
Indoor fan speed has been out of control for over 1 minute
☆
X
Indoor room temp. or evaporator sensor is open circuit or short circuit
☆
On
Over current protection of the compressor occurs 4 times
X
☆
EEROM error
On
☆
No over-zero signal
☆
☆
r
Extinguish
☆
Flash at 5Hz
For heat pump mode:
Failure phenomenon
Operation
lamp
Timer
lamp
Defrosting
lamp
Over current protection of the compressor occurs 4 times
☆
X
☆
Indoor fan speed has been out of control for over 1 minute
X
☆
☆
No over-zero signal
☆
☆
☆
Temp. sensor on indoor evaporator is open circuit or short circuit
X
X
☆
Indoor room temp. sensor is open circuit or short circuit
X
☆
X
EEROM error
On
☆
X
r
Extinguish
☆
Flash at 5Hz
26
Содержание HKEI-HCNI 263 G
Страница 1: ...Cover HKEI HCNI 263 G HKEI HCNI 353 G HKEI HCNI 503 G HOKKAIDO SERVICE MANUAL ...
Страница 10: ...Service manual 4 Refrigerant cycle diagram Cooling only Heat pump mode 7 ...
Страница 12: ...Service manual 6 Wiring diagram HKEI HCNI 263 353 503 G Indoor Outdoor 9 ...
Страница 13: ...Service manual 10 ...