Service manual
8.9 Auto
mode
8.9.1 The air conditioner automatically selects one of the following operation modes: cooling, heating or fan
only according to the temp
erature
difference between room temperature (TA) and set temperature (TS)
.
-1
TA-TS
2
Heating (fan only at cooling only)
Fan only
Cooling
8.9.2 The indoor fan blows automatically in corresponding selected mode
The motion of indoor fan’s blade should accord with the selected operation mode
hould be carried out for at least 15 minutes once selected. If the compressor cannot start for
8.10 Force cooling function
8.10.1 Select forced cooling function with the forced cooling button or the switch
8.10.2 The compressor is unconditionally turned on, after 30 minutes cooling operation whose fan mode is set
as low, the A/C operates at the DRY mode with a set temp. of 24
°
8.10.3 All protections of remote control cooling are available at forced cooling operation
ode
8.11.1 The sleep function is available at cooling, heating or auto mode
intain as a constant and the
8.9.3
8.9.4 One mode s
15 minutes, reselect the operation mode according to the room temp. and set temp., or reselect when the set
temp. varies
8.10.4 Forced
Auto function
Select forced auto function with the forced auto button or the switch.
In forced auto status the A/C operates at remote control mode with a set temp. of 24
°
8.11 Sleep m
8.11.2 Cooling:
The set temperature rise 1
°
per hour. Two hours later, the set temperature will ma
fan speed is kept at low speed.
23
Содержание HKEI-HCNI 263 G
Страница 1: ...Cover HKEI HCNI 263 G HKEI HCNI 353 G HKEI HCNI 503 G HOKKAIDO SERVICE MANUAL ...
Страница 10: ...Service manual 4 Refrigerant cycle diagram Cooling only Heat pump mode 7 ...
Страница 12: ...Service manual 6 Wiring diagram HKEI HCNI 263 353 503 G Indoor Outdoor 9 ...