-4-
GENERAL INFORMATION
Outline of specific features
ECO-FRIENDLY REFRIGERANT R410A
As R410A refrigerant contains no chlorine, it does not damage ozone.
POWER CONTROL THROUGH "DC INVERTER"
Power is supplied according to real needs of comfort, thus permitting a sure energy saving.
INFRARED REMOTE CONTROLLER
All available functions of the air conditioner can be set by using the infrared remote controller,
whose LCD panel immediately shows the operating parameters.
ON TIMER / OFF TIMER
ON Timer,
allows to program the air conditioner's start within 24 hours. If the set time does not
exceed 10 hours, the TIMER ON is set by 0.5 hours' steps. If the set time exceeds 10 hours,
the TIMER ON is set by 1 hour's steps.
OFF Timer,
allows to program the air conditioner's stop within 24 hours. If the set time does not
exceed 10 hours, the TIMER OFF is set by 0.5 hours' steps. If the set time exceeds 10 hours,
the TIMER OFF is set by 1 hour's steps.
The air conditioner's start and/or stop may also be programmed in sequence, within 24 hours.
DRY FUNCTION
When "DRY" function is selected, the air conditioner strongly reduces humidity inside the room,
and also keeps the room temperature at a constant value.
ADVANCED CONTROL FOR INDOOR UNIT'S FAN
Thermostatic stops.
In Heating mode, when set temperature has been reached inside the
room, the compressor stops and the indoor fan speed is lowered to avoid cold drafts.
Hot Keep.
At the beginning of operation in Heating mode, the indoor fan will start only 5 minutes
later, i.e. when the temperature of indoor heat exchanger is adequate.
MICROCOMPUTER CONTROLLED DEFROSTING FUNCTION (HEATING MODE)
The microcomputer on printed circuit board can monitor all decreases in heating power of the air
conditioner caused by frosting on outdoor heat exchanger, and inputs the signal for automatic
defrosting; a LED lights up when this function is activated.
THERMOSTAT UNDER MICROCOMPUTER CONTROL
The thermostat being controlled by microcomputer allows remarkable energy saving and provides
more comfort, as the room temperature is checked with the greatest precision.
Содержание HCKI 275 XS
Страница 41: ...NOTES ...
Страница 42: ...NOTES ...