background image

6

 Adres producenta/ Adresse des Herstellers/ Manufacturer’s Address/ Адрес производителя 

GTV Poland Sp. z o.o. Sp. k., ul. Przejazdowa 21, 05-800 Pruszków, www.hoegert.com

EN

USER’S MANUAL 

DIGITAL UNIVERSAL MULTIMETER HT1E606

Thank you for purchasing our product. Our product, manufactured to a high 

standard, will provide years of trouble-free operation if used in accordance 

with the instructions and properly maintained.

TABLE OF CONTENTS

1.  General information

2.  General safety conditions

3.  Description and functions

4. Measurements

  

4.1. Inductive measurement NCV

  

4.2. Measurement of voltage U DC/AC

  

4.3. Measurement of voltage I DC/AC

  

4.4.  Resistance  measurement

  

4.5.  Capacity  test

  

4.6.  Frequency  test

  

4.7.  Temperature  test

  

4.8.  Continuity  test

  

4.9. HFE transistor test

5. Specifications

  

5.1.  Technical  Specification

  

5.2.  Electrical  specification

6. Maintenance

  

6.1. Battery replacement

  

6-2. Fuse replacement

  

6-3.  Maintenance

Environmental protection

Symbol indicating separate collection of electrical and electronic equipment waste. Used electrical appliances are 

secondary raw materials - they must not be disposed of in household waste, as they contain substances hazardous to 

human health and the environment! Please actively help us to manage natural resources and protect the environment by 

handing over used equipment to the waste electrical equipment storage point. To reduce the amount of waste disposed of, it 

is necessary to reuse, recycle or recover it in another form.

1. GENERAL INFORMATION

The device is intended for use both in private households and for commercial purposes. The HT1E606 Digital Multimeter is an inno-

vative, powerful, reliable, battery-powered, full-featured instrument with AC and DC voltage measurement up to 2000V, contactless 

NCV and temperature measurement, with a large LCD screen showing 4000 characters.

The meter is equipped with an overload protection circuit that can be used to measure DC and AC voltage, AC and DC current, 

resistance, capacity, frequency, live wires, battery voltage, non-contact NCV detection, diode and circuit continuity.

Any other use is not intended and may lead to property damage or even personal injury. Use the device only in accordance with this 

manual. The manufacturer does not assume any liability for damage caused by improper use. The device is not a measuring device 

within the meaning of the „Measurement Law”.

2. GENERAL SAFETY CONDITIONS

It is within the scope of the owner and user’s responsibility to read, understand and follow these rules: 

IMPORTANT:

 Please read this manual carefully. Please pay special attention to the requirements of safe use, warnings and 

notices. Use the product correctly and carefully for the purposes for which it is intended. Failure to do so may result in 

damage and/or harm to health and will void the warranty. Please keep this manual in a safe place for further use. When 

passing the device on to another person, also give them the manual.

•  Please use the device only for the purpose intended for the device.

•  Please keep the device away from heat, direct sunlight, moisture (under no circumstances immerse in liquid substances) and 

sharp edges. Do not operate the device with wet hands.

•  Do not leave the device running unattended. Always switch off the unit before leaving the room.

•  Check regularly that the device is not damaged. If damage is detected, stop using the device.

•  For the safety of children, please do not leave any freely accessible parts of the packaging (plastic bags, cartons, polystyrene, etc.).

WARNING

Don’t let the kids play with the foil. Danger of suffocation!

This device is not intended for use by persons with reduced physical, sensory or mental capabilities or lack of experience and/or 

skills, unless such persons are accompanied and supervised by persons responsible for their safety or have received precise instruc-

Содержание HT1E606

Страница 1: ...go a do 2000V pomiaru bezdotykowego NCV oraz temperatury z du ym ekranem LCD pokazuj cym 4000 znak w Miernik jest wyposa ony w obw d zabezpieczaj cy przed przeci eniem kt ry mo e by u ywany do pomiaru...

Страница 2: ...ie wysokich temperaturach o ile to mo liwe Unikaj ryzyka pora enia pr dem podczas pomiaru napi przekraczaj cych 30 V AC lub 60 V DC Przed pomiarem pr du nale y wy czy zasilacz i od czy go od obwodu pr...

Страница 3: ...akresie oznaczonym F 3 Przy o y ko c wki przewod w pomiarowych do mierzonego elementu 4 Odczyta na wy wietlaczu warto pojemno ci 4 6 POMIAR CZ STOTLIWO CI HZ 1 Wetkn ko c wk czerwonego przewodu pomiar...

Страница 4: ...iomu baterii Auto wy czenie 5 2 SPECYFIKACJA ELEKTRYCZNA 1 Test ci g o ci i indukcyjny Test ci g o ci NCV 2 Napi cie U DC AC Funkcja Zakres Rozdzielczo Dok adno Max Napi cie UDC V 400mV 100uV 0 5 5d 2...

Страница 5: ...0 C 1 C 1 8d 1 5 15d 1000 C 400 C 1000 C 1 C 6 KONSERWACJA 6 1 Wymiana baterii Je li symbol pojawia si na wy wietlaczu LCD podczas u ytkowania miernika nale y wymieni bateri aby zapobiec nieprawid o w...

Страница 6: ...racters The meter is equipped with an overload protection circuit that can be used to measure DC and AC voltage AC and DC current resistance capacity frequency live wires battery voltage non contact N...

Страница 7: ...ice on off 2 SELECT Press the SELECT button to switch the function and unit of measurement 3 HOLD BL HOLD to stop the reading during the measurement you can press the HOLD button and then the measurem...

Страница 8: ...nd of the black test lead into the COM terminal 2 Turn the function knob to the position marked Hz 3 Put the ends of the test leads to the measured element 4 Read the frequency value on the display 4...

Страница 9: ...n Accuracy Max UDC voltage V 400mV 100uV 0 5 5d 2000V 4V 1mV 40V 10mV 0 8 5d 400V 100mV 2000V 1V 2 0 5d UAC voltage V 400mV 100uV 0 5 5d 2000V 4V 1mV 40V 10mV 0 8 5d 400V 100mV 2000V 1V 2 0 5d 3 Volta...

Страница 10: ...ANCE 6 1 Battery replacement If the symbol appears on the LCD while using the meter replace the battery to prevent incorrect reading of measurements 1 Disconnect the test wires Turn off the power 2 Us...

Страница 11: ...NCV und Temperaturmessung mit einem gro en LCD Display mit 4000 Zeichen Das Messger t ist mit einem Stromkreis zum Schutz vor berlastung ausgestattet das zur Messung von Gleich und Wechselspan nung W...

Страница 12: ...iten Schalten Sie vor der Strommessung das Netzteil aus und trennen Sie es vor der Messung vom Stromkreis Achten Sie w hrend des Batteriewechsels auf die Polarit t Elektrische Symbole Hochspannung m g...

Страница 13: ...ennzeichneten Bereichs 3 Legen Sie die Enden der Messleitungen an das gemessene Element an 4 Lesen Sie den Wert der Kapazit t auf dem Display ab 4 6 Messung der Frequenz Hz 1 F hren Sie die Spitze der...

Страница 14: ...5 2 ELEKTRISCHE SPEZIFIKATION 1 Kontinuit ts und induktiver Test Kontinuit tstest NCV 2 Spannung U DC AC Funktion Bereich Aufl sung Genauigkeit Max Spannung UDC V 400mV 100uV 0 5 5d 2000V 4V 1mV 40V 1...

Страница 15: ...das Symbol auf dem LCD Display erscheint wenn das Messger t in Betrieb ist wechseln Sie die Batterie aus um falsche Messwerte zu vermeiden 1 Testleitungen trennen Stromversorgung abschalten 2 Mithilfe...

Страница 16: ...tellers Manufacturer s Address GTV Poland Sp z o o Sp k ul Przejazdowa 21 05 800 Pruszk w www hoegert com RU HT1E606 1 2 3 4 4 1 NC 4 2 U DC AC 4 3 I DC AC 4 4 4 5 4 6 4 7 4 8 4 9 NPN PNP 5 5 1 5 2 6...

Страница 17: ...GTV Poland Sp z o o Sp k ul Przejazdowa 21 05 800 Pruszk w www hoegert com E 8 HT1E606 HT1E605 IEC61010 1 400 CATIII 2 100 30 60 C AC DC DC 3 1 ON OFF 2 SELECT SELECT 3 HOLD BL HOLD HOLD HOLD HOLD 2...

Страница 18: ...Poland Sp z o o Sp k ul Przejazdowa 21 05 800 Pruszk w www hoegert com 4 3 I DC AC 1 mA COM 2 A A 3 4 4 4 1 OL 2 COM 3 4 4 5 F 1 COM 2 F 3 4 4 6 1 COM 2 3 4 4 7 TEMP 1 C COM 2 TEMP 3 4 4 8 1 COM 2 3 4...

Страница 19: ...ta Hold ABS 3 s 5 2 1 1 NCV 2 U DC AC UDC 400mV 100uV 0 5 5d 2000V 4V 1mV 40V 10mV 0 8 5d 400V 100mV 2000V 1V 2 0 5d UAC 400mV 100uV 0 5 5d 2000V 4V 1mV 40V 10mV 0 8 5d 400V 100mV 2000V 1V 2 0 5d 3 I...

Страница 20: ...m 4 R 400 0 1 1 0 5d 400M 4K 1 40K 10 1 0 5d 400K 100 4M 1K 40M 10K 1 2 8d 400M 100K 4 10d 5 F 40nF 10pF 4 0 5d 400uF 400nF 100pF 4uF 1nF 40uF 10nF 400uF 100nF 6 Cz stotliwo Hz 4kHz 1Hz 1 5 8d 4MHz 40...

Страница 21: ...n grand affichage LCD affichant 4000 caract res Le mesureur est quip d un circuit de protection contre les surcharges qui peut tre utilis pour mesurer la tension CA et CC le courant CA et CC la r sist...

Страница 22: ...les piles SYMBOLES LECTRIQUES Tension dangereuse Mise la terre CA courant alternatif Avertissement CC courant continu Double isolation CA ou CC Fusible 3 DESCRIPTION ET FONCTIONS 1 ON OFF allumer tei...

Страница 23: ...Approchez les extr mit s des c bles de mesure l l ment mesur 4 Lire la valeur de fr quence sur l affichage 4 7 Mesure de Temp rature TEMP 1 Le dispositif est quip d un c ble suppl mentaire destin la...

Страница 24: ...uV 0 5 5d 2000V 4V 1mV 40V 10mV 0 8 5d 400V 100mV 2000V 1V 2 0 5d Tension UAC V 400mV 100uV 0 5 5d 2000V 4V 1mV 40V 10mV 0 8 5d 400V 100mV 2000V 1V 2 0 5d 3 Tension I CC CA Fonction tendue R solution...

Страница 25: ...t sur l affichage LCD pendant l utilisation du mesureur il faut remplacer la pile pour pr venir une lecture incorrecte des mesures 1 D connectez les c bles de test Coupez le courant 2 Utilisez un tour...

Отзывы: