10
Adres producenta/ Adresse des Herstellers/ Manufacturer’s Address/ Адрес производителя
GTV Poland Sp. z o.o. Sp. k., ul. Przejazdowa 21, 05-800 Pruszków
5-4. DC voltage
Range
Resolution
Accuracy
400 µA
0.1 µA
±(1.2% r 8 digits)
4000 µA
1 µA
40 mA
10 µA
400 mA
100 µA
4 A
1 mA
10 A
10 mA
Overload protection:
µA and mA ranges: fuse F 0.5 A /600 V. Ranges 4 A and 10 A: fuse F 10A /600 V. Max. Output current:
INPUT socket: 200 mA
Socket „A”: 10 A.
(For measurements > 5A: duration <10 seconds, interval > 15 minutes)
A drop in voltage: ranges 400 µA, 40 mA and 4 A: 40 mV
Ranges 4000 µA, 400 mA i 10 A: 400 mV
5-5. AC current amperage
Range
Resolution
Accuracy
400 µA
0.1 µA
±(1.5% r 8 digits)
4000 µA
1 µA
40 mA
10 µA
400 mA
100 µA
4 A
1 mA
±(2.0% r 10 digits)
10 A
10 mA
Overload protection:
µA and mA ranges: fuse F0.5 A / 600 V. Ranges 4 A and 10 A: fuse F10 A / 600 V. Max. Output current:
INPUT socket: 200 mA
Socket „A”: 10 A. (For measurements> 5 A: duration <10 seconds, interval> 15 minutes)
Voltage drop: ranges 400 µA, 40 mA and 4 A: 40 mV
Ranges 4000 µA, 400 mA i 10 A: 400 mV
Frequency range: 40 Hz ~ 400 Hz
Answer: Average, calibrated in RMS
5-6. Resistance
Range
Resolution
Accuracy
400 Ω
0.1 Ω
±(1.5% r 3 digits)
4 KΩ
1 Ω
40 KΩ
10 Ω
400 KΩ
100 Ω
4 MΩ
1 KΩ
40 MΩ
10 KΩ
Open circuit voltage: approximately 0.25 V. Overload protection: 250 V DC / AC RMS