Passenger Tire Changers Service Manual 07-13 Rev.B
17
Remove the motor terminals cover and disconnect all wires from
terminals.
Select the multimeter in Ohm and check if there is continuity
between ends of each wire.
Cross the wire check to make sure that wires are not in short
circuit.
TO CHECK THE CABLE ON INVERTER SWITCH:
Remove the foot pedal assembly from the cabinet
4.2
Remove the switch from the pedal assembly
4.2
Remove the motor terminals cover and disconnect all wires from terminals.
Select the multimeter in Ohm and check if there is continuity between ends of each wire.
Cross the wire check to make sure that wires are not in short circuit.
TO REPLACE THE CABLE ON ELECTRONIC INVERTER:
Release cable strain relief on the electric box and on the motor.
Take the wrong cable away.
Insert the new cable through the strain relief.
IMPORTANT! USE ONLY APPROVED CABLE. GROUND WIRE MUST BE LITTLE
LONGER THAN THE OTHER ONES TO ALLOW THE GROUND IN CASE OF PHASE
CABLE BREAKAGE.
NOTE:
Before connecting the wires ends, tighten all terminals nuts on the motor.
Fix new fastons to the cable ends.
Connect the wires to the motor and inverter terminals.
Mount the motor terminal cover.
IMPORTANT: WHEN REMOUNTING THE MOTOR TERMINALS COVER BE CAREFUL NOT TO CRUSH
WIRES.
Plug the machine to wall.
Turn the machine on and check if it works fine.
Disconnect the machine from the power supply.
Mount the side panel to the cabinet.
Fix the electric box to the cabinet again
4.1
TO REPLACE THE CABLE ON INVERTER SWITCH:
Replace the cable following
4.2
4.6 TURNTABLE MOTOR M1 AND BELT: CHECK AND REPLACEMENT
:
1h
:
2 End keys 13,1 end key 17mm, medium cross screwdriver, 7mm tube type wrenches, 3 mm allen key,
multimeter, loctite, extractor.
:
Defective centerpost motor may cause the following malfunction:
1. Motor is noisy.
2. Motor is burnt.
3. Low turntable torque.
TO CECK THE MOTOR WHEN IT SHOWS LOW TORQUE OR IT IS NOISY:
Refer
to
4.5