Configuration
20
HP-306
Display Option
Menu item
Description
CLEArtot
no
Yes
No
Clear Total
Clears accumulated total and sets
TOTAL display to zero.
10000000
tA9
Tag
Number
User defined 5-digit number.
(#####)
AuErAgE
FAC NN
Linear
Average
Linearization Method
Sets the flow calculation method to
average K-factor or K-factor table.
00000.000
FAC d
K-factor Decimal Point
Set K-factor decimal point location.
1.000
A FAC
Average K-factor
Enter average K-factor.
PointS
20
2
to
20
Number of Points
Sets the number of entries in the
linearization table.
4999.981
Fr 01
0
to
5000
Frequency 1-20
Enter a frequency in Hz for each
entry in the table. Decimal point is
fixed.
1.000
FAC01
K-factor 1-20
Enter a k-factor in pulses/gal for
each entry in the table.
1.000
C FAC
0.001
to
99999.999
Correction Factor
User defined number between 0.001
and 99999.999 to multiply flow and
total. Default 1.0.
tot unit
100
100 = GAL
110 = FT3
140 = LIT
150 = M3
180 = BBL
Total Units
Select Total units.
If custom is selected all indicators
are off. (gal, lit, ft3, m3, bbl,
custom)
0000000.0
tot d
Total Decimal Point
Set Total decimal point location.
Содержание HIT-2A
Страница 2: ......
Страница 6: ...HP 306...
Страница 10: ...Introduction 2B HP 306 This page intentionally left blank...
Страница 14: ...Specification 6 HP 306 This page intentionally left blank...
Страница 18: ...Theory of Operation 10 HP 306 This page intentionally left blank...
Страница 20: ...Installation 12 HP 306 TTL Redi Pulse Pick up with DC Power Reset Input Heater Option...
Страница 26: ...Installation 18 HP 306 This page intentionally left blank...
Страница 34: ...Operation and Maintenance 26 HP 306 This page intentionally left blank...