Appendix B
- Communications
38
HP-306
System
Command
Description/Response/Comments
RT
Read Total
“TOTAL = (DATA)”
(DATA)
=
“0”
to the following maximums:
“99999.999”
if TD = 3
“999999.99”
if TD = 2
“9999999.9”
if TD = 1
“ 99999999”
if TD = 0
RR
Read Rate
“FLOW = (DATA)”
(DATA)
=
“0”
to the following maximums:
“99999.999”
if RD = 3
“999999.99”
if RD = 2
“9999999.9”
if RD = 1
“ 99999999”
if RD = 0
ST
1
Set Total
See ST command above.
CN
Adjust 4mA output point
“CN=#(DATA)”
(DATA)
is the integer value that the HIT-2A sends to the
4-20mA converter to output 4mA
This parameter is passed to the HIT-2A to adjust the 4mA
output point of the device. This value is used in production
at the test step to calibrate the 4mA output point.
“CN”
will cause an Invalid Command response and absence of the
# symbol will cause the HIT-2A to ignore the data.
CM
Adjust 20mA output point
“CM=#(DATA)”
(DATA)
is the integer value that the HIT-2A sends to the
4-20mA converter to output 20mA
This parameter is passed to the HIT-2A to adjust the 20mA
output point of the device. This value is used in production
at the test step to calibrate the 20mA output point.
“CM”
will cause an Invalid Command response and absence of the
# symbol will cause the HIT-2A to ignore the data.
Содержание HIT-2A
Страница 2: ......
Страница 6: ...HP 306...
Страница 10: ...Introduction 2B HP 306 This page intentionally left blank...
Страница 14: ...Specification 6 HP 306 This page intentionally left blank...
Страница 18: ...Theory of Operation 10 HP 306 This page intentionally left blank...
Страница 20: ...Installation 12 HP 306 TTL Redi Pulse Pick up with DC Power Reset Input Heater Option...
Страница 26: ...Installation 18 HP 306 This page intentionally left blank...
Страница 34: ...Operation and Maintenance 26 HP 306 This page intentionally left blank...