[35]
EN
CERAMIC T
OWER HEA
TER
Swing function
• When the heater is running, press the “oscillation” button (I) to activate
the horizontal oscillatory movement. Press the “oscillation” button (I)
again to disable the horizontal oscillatory movement. When the heater
is turned off or goes into standby mode, the oscillatory movement also
stops.
Temperature short circuit protector
• The device has a temperature sensor with an open circuit protection
function against short circuits.
• In any of the device’s modes, this temperature sensor, if activated,
displays on the display (H) “E1” or “E2” and flashes constantly,
preventing any button from working and making a buzz sound 10
times.
Safety protection
• When the ambient temperature is above 50º C the display (H) shows
“FF” and flashes 1 time per second, 75 times. In this case, no button will
work and only turning the device off will make it leave this protection
mode and be operational again.
Toppling over protection function
• Regardless of whether it is on or off, when the appliance falls, the
system immediately switches off all heating components, the display
(H) shows “E3” and the buttons stop working.
ECO energy saving function
• Select the ECO energy saving mode on the heater according to the
room temperature and the temperature setting on the machine. Select
the most suitable mode in order to achieve the purpose of energy
saving.
Remote control
• The remote control has the same buttons and functions as the control
panel (B), but with the facility to be able to operate the device remotely.