Hochiki FireNET L@titude S723 Скачать руководство пользователя страница 1

Version 1.05 |   May 2019 |   MAN-1436HA

FireNET L@titude Network
Module (S723) Information
Guide

Содержание FireNET L@titude S723

Страница 1: ...Version 1 05 May 2019 MAN 1436HA FireNET L titude Network Module S723 Information Guide...

Страница 2: ...4 Warranty Service 5 Advanced Replacements 5 Overview 6 Installation 7 Before You Begin 8 Placement 8 Network Connections 9 Testing 11 Troubleshooting 13 Specifications 14 Electrical 14 Operating Env...

Страница 3: ...ications not expressly approved by Hochiki America Corporation could void the user s authority to operate this equipment under the rules and regulations of the FCC Operation is subject to the followin...

Страница 4: ...mber is assigned when l Tech Support acknowledges a possible product failure l A product was damaged during shipping l An incorrect product was shipped l An order was placed using an incorrect part nu...

Страница 5: ...ll contractors who maintain an acceptable line of credit Initiate the advanced replacement process by requesting an RMA number from a Tech Support representative Advanced replacements can be shipped t...

Страница 6: ...used in conjunction with the Network Module provides tolerance against open and short circuit trouble conditions The L titude Network Module can be configured to operate in a bridge mode which enables...

Страница 7: ...from the panel q Connect the 40 conductor connector of the Network Module to the 40 conductor connector of the LCD Main Processor Board q Secure the Network Module to the LCD Main Processor Board wit...

Страница 8: ...on as quick and easy as possible Acquire the following item that is not included but may be required for installation l Ground Strap A ground strap is required for handling circuit boards The ground s...

Страница 9: ...s to NETWORK IN and NETWORK OUT terminals of the FireNET L titude Fire Alarm Control Panel s Main Back Board after installing the Network Module The following figure illustrates the typical network co...

Страница 10: ...minals must be connected together to prevent an OPEN CIRCUIT TROUBLE indication Bridge networking is supported for FireNET and FireNET Plus panels Advanced features are not available when using bridge...

Страница 11: ...Heartbeat Red Identifies functional status LED 2 Tx Comms Green A blinking green light indicates that the module is transmitting data LED 3 Rx Comms Green A blinking green light indicates that the mo...

Страница 12: ...ion present when flashing LED9 Full Duplex Yellow Full duplex on half duplex off LED 10 Ethernet Speed Red 10MHz off 100MHz on LED 12 Communication Green Communication present when flashing Hochiki Am...

Страница 13: ...also be shown when the network is disconnected or when the NET OUT wire is disconnected Network Panel Missing This event indicates that another panel is configured but has not been found on the networ...

Страница 14: ...work Vision Annunciator 21 30V DC L titude Fire Alarm Control Panel 24V DC Operating Environment Dry indoor use only Temperature Range 23oF 5oC 120oF 49oC Relative Humidity Up to 95 non condensing Hoc...

Страница 15: ...ss X 6 9 H Heartbeat 11 L LCD Main Processor Board 7 N Network 6 7 13 14 T Terminals 9 Trouble 6 10 Hochiki America Corporation FireNET L titude Network Module S723 Information Guide Version 1 05 May...