![Hoberg 04292 Скачать руководство пользователя страница 19](http://html.mh-extra.com/html/hoberg/04292/04292_manual_2143052019.webp)
19
EN
* PLEASE NOTE:
• The
specifi ed values are emission values and they do not therefore also represent
safe workplace values. Although there is a correlation between emission and immis-
sion levels, it cannot reliably be inferred from this whether additional precautionary
measures are necessary or not. Factors which infl uence the current immission level
existing at a workplace include the nature of the workspace, other noise sources,
e. g. the number of machines and other working processes taking place nearby. The
permitted workplace values can also vary from country to country. However, this in-
formation should help you to be able to make a better assessment of hazard and risk.
• The
specifi ed total vibration value and the specifi ed noise emission values have
been measured using a standardised testing method and can be used to compare
one power tool with another one. The emission values can also be used to make a
preliminary assessment of the level of pollution.
• The vibration and noise emissions may vary from the specifi ed values when the
power tool is actually used, depending on the way in which the power tool is used,
in particular what kind of workpiece is being machined.
Troubleshooting
If the device does not work properly, check whether you are able to rectify the problem
yourself. If the problem cannot be solved with the steps that are listed, contact our
customer service department.
Never attempt to repair a defective device yourself!
Fault
Cause
Fix
The device does not
start up when it is
switched on.
No electrical contact be-
tween the device and the
battery
Remove the battery, perform
a visual check of the contacts
and insert it again
Battery charge level too
low
Charge up the battery
Battery too hot / cold
Use a battery at tempera-
tures of approx. -20 to +50°C,
allow it to warm up or cool
down if necessary
Fault in the battery
Remove the battery from the
device and reinsert it; if the
device still does not start up,
the battery is defective and
needs to be replaced
Device too hot
Allow the device to cool down
Electromagnetic fault or
error in the device
Remove the battery from the
device and reinsert it; switch
the device on again, if it still
does not start up, the device
is defective and needs to be
replaced
Moisture in the device or
battery
Allow the device and battery
to dry