5-11. Connecting Input Power
804912-A
L1
L2
240 VAC, 1
2
!
Installation must meet all National
and Local Codes
−
have only qualified
persons make this installation.
!
Disconnect and lockout/tagout input
power before connecting input con-
ductors from unit.
!
Always connect green or green/yel-
low conductor to supply grounding
terminal first, and never to a line ter-
minal.
See rating label on unit and check input volt-
age available at site.
1
Plug (NEMA Type 6-50P)
2
Receptacle
[NEMA Type 6-50R (Customer
Supplied)]
3
Input Power Cord.
Connect directly to line disconnect device if
hard wiring is required.
4
Disconnect Device (switch shown in
the OFF position)
5
Disconnect Device Grounding Terminal
6
Disconnect Device Line Terminals
7
Green Or Green/Yellow Grounding
Conductor
8
Black and White Input Conductor (L1
and L2)
Connect green or green/yellow grounding
conductor to disconnect device grounding
terminal first.
Connect input conductors L1 and L2 to
disconnect device line terminals.
9
Over-Current Protection
Select type and size of over-current
protection using Section 5-10 (fused
disconnect switch shown).
Connect plug to receptacle if hard wiring
method is not used.
Close and secure door on disconnect device.
Remove lockout/tagout device, and place
switch in the On position.
1
3
1
=GND/PE Earth Ground
4
L1
L2
8
7
5
6
9
Содержание IronMan 240
Страница 4: ......
Страница 26: ... A complete Parts List is available at www HobartWelders com OM 284833 Page 22 5 13 Weld Parameters ...
Страница 27: ... A complete Parts List is available at www HobartWelders com OM 284833 Page 23 284702 B ...
Страница 32: ...OM 284833 Page 28 SECTION 8 ELECTRICAL DIAGRAM Figure 8 1 Welding Power Source Circuit Diagram ...
Страница 33: ...OM 284833 Page 29 284828 A ...