OM-944 Page 30
7-2.
Typical MIG Process Control Settings
These settings are guidelines only. Material and wire type, joint design, fitup,
position, shielding gas, etc. affect settings. Test welds to be sure they comply to
specifications.
NOTE
1/8 or
.125 in
Material thickness determines weld
parameters.
Convert Material
(.001 in = 1 ampere)
.125 in = 125 A
Select Wire Size
Wire Size
Amperage Range
.030 in
.035 in
.023 in
40 – 145 A
50 – 180 A
30 – 90 A
.035 in
Select Wire Speed
Select Voltage
Wire
Recommendation
.030 in
.035 in
.023 in
2 in per ampere
1.6 in per ampere
3.5 in per ampere
Wire Speed
2 x 125 A = 250 ipm
1.6 x 125 A = 200 ipm
3.5 x 125 A = 437 ipm
Set voltage midway between high/low voltage.
Low voltage: wire stubs into work
High voltage: arc is unstable (spatter)
125 A based on 1/8 in
Thickness to
(Amperage)
material thickness
Size
(Approx.)
Amperage (A)
ipm = inch per minute
Ref. 802 439
Voltage controls height and width of
weld bead.
Wire speed (amperage) controls weld pe-
netration (wire speed = burn-off rate)
Содержание H-10
Страница 4: ......
Страница 24: ...OM 944 Page 20 4 2 Weld Parameters For 115 VAC Model 196 052 ...
Страница 25: ...OM 944 Page 21 4 3 Weld Parameters For 230 VAC Model 196 081 A ...
Страница 31: ...OM 944 Page 27 SECTION 6 ELECTRICAL DIAGRAM 194 324 NEUTRAL Figure 6 1 Circuit Diagram For 115 VAC Model ...
Страница 32: ...OM 944 Page 28 194 325 Figure 6 2 Circuit Diagram For 230 VAC Model ...
Страница 46: ...Notes ...