Selecting A Location And Connecting Input Power For 115 VAC Model
1
Rating Label
2
Grounded Receptacle
A 115 volt, 20 ampere individual
branch circuit protected by time-de-
lay fuses or circuit breaker is re-
quired.
3
Plug From Unit
Select extension cord of 14 AWG
for up to 50 ft (15 m) or 12 AWG for
50 up to 200 ft (61 m).
Y
Special installation may be
required where gasoline or
volatile liquids are present –
see NEC Article 511 or CEC
Section 20.
2
1
3
18 in
(460 mm)
18 in
(460 mm)