OM-944 Page 13
3-3.
Process/Polarity Table
Cable Connections
Process
Polarity
Cable To Gun
Cable To Work
GMAW – Solid wire with shield-
ing gas
DCEP – Reverse polarity
Connect to positive (+) out-
put terminal
Connect to negative (–) output
terminal
FCAW – Self-shielding wire –
no shielding gas
DCEN – Straight Polarity
Connect to negative (–)
output terminal
Connect to positive (+) output
terminal
3-4.
Changing Polarity
1
Lead Connections For Direct
Current Electrode Positive
(DCEP)
2
Lead Connections For Direct
Current Electrode Negative
(DCEN)
Always read and follow wire
manufacturer’s recommended po-
larity, and see Section 3-3.
Close door.
1
Ref. 196 052
2