OM-944 Page 17
3-8.
Electrical Service Guide For 230 VAC Model
Input Voltage
230
Input Amperes At Rated Output
20
Max Recommended Standard Fuse Or Circuit Breaker Rating In Amperes
20
Min Input Conductor Size In AWG/Kcmil
14
Max Recommended Input Conductor Length In Feet (Meters)
66 (20)
Min Grounding Conductor Size In AWG/Kcmil
12
Reference: 1996 National Electrical Code (NEC)
S-0092-J
3-9.
Installing Wire Spool And Adjusting Hub Tension
S-0499
15/16 in
Standard Wire Spool (8 in)
1 Lb Wire Spool (4 in)
Turn wingnut. When a slight force is
needed to turn spool, tension is set.
Tools Needed:
Adjusting Hub Tension
Install spool so welding wire feeds from bottom.
Содержание H-10
Страница 4: ......
Страница 24: ...OM 944 Page 20 4 2 Weld Parameters For 115 VAC Model 196 052 ...
Страница 25: ...OM 944 Page 21 4 3 Weld Parameters For 230 VAC Model 196 081 A ...
Страница 31: ...OM 944 Page 27 SECTION 6 ELECTRICAL DIAGRAM 194 324 NEUTRAL Figure 6 1 Circuit Diagram For 115 VAC Model ...
Страница 32: ...OM 944 Page 28 194 325 Figure 6 2 Circuit Diagram For 230 VAC Model ...
Страница 46: ...Notes ...