internal
thread
air
outlet
Pressurized vessels are hazardous for user and vicinity
in case of negligence or mishandling. Always use filled
air cylinders and extinguishers with due diligence.
Never overfill air cylinders. Maximum pressure: 300 bar.
Use only approved air cylinders with certification.
Filling of compressed air
After closing, the filled container needs to be charged with working
pressure (18 bar). Matching compressed air cylinders and filling
adapters are available as accessories (see page 5).
Before connection:
Please pay attention to the following points before you connect
the filling adapter to the compressed air cylinder:
outer
thread
O-ring
A full compressed air cylinder (2 liters) is sufficient for
app. 60 fillings of a HiPRESS 2
The threads of air cylinder and regulator must be free of
dirt and debris. Clean if necessary, but do not lubricate.
Check the condition of the O-ring at the pressure reducer.
Replace it in case of cracks or loss.
Do not use tools to tighten the knurled hand-wheel of the
pressure reducer.