If it is necessary to recirculate the SSQV back into the suction pipe, please refer to the instructions below.
Miscellaneous hose clamps, suction pipe fitting and return hose are not included in this kit.
For 1” ID Hose P/N : 71002-XA001
SSQV Recirculation Fitting (sold separately) For 19mm ID Hose P/N : 71002-AK003
For 29mm ID Hose P/N : 71002-AK004
1. Remove 4 bolts (per diagram) and remove the cover.
NOTE
Do not remove the remaining 4 bolts as they are to stay
affixed to the SSQV main body.
2. After removal of the cover, the recirculation fitting can
be removed.
3. Install the Recirculation Fitting. Reinstall the cover and
retighten the 4 bolts.
9
1
SSQV
7
QT
Image
Remarks
No.
4
5
6
No.
Instruction
Manual
1
C-clip
O-ring
1
1
2
3
No.
Description
8
9
Vacuum Filter
1
1
1
1
6-4-6mm
T-Fitting
4-4-4mm
T-Fitting
Tie Wrap
3
QT
Image
Remarks
Description
QT
Image
Remarks
Description
Check the following after the installation process is complete.
(1) Check the following before starting the engine:
●
Make sure all pipes and hoses are routed and connected correctly.
●
Make sure all hose clamps are tightened.
●
Make sure the negative cable terminal is securely attached to the battery.
●
Make sure all bolts and nuts are tightened.
●
Make sure all installed components do not come in contact with other parts.
(2) Start the engine and check the following:
●
Make sure air is not leaking.
●
Make sure the RPM rises smoothly after revving the engine 2-3 times while in neutral.
●
Make sure the installed parts are not hitting each other.
●
Make sure there are no unusual conditions found while idling.
●
Make sure there are no loose bolts after turning off the engine. Re-tighten if necessary.