3.5 Maximum Number
of Flown COHEDRA
®
CDR 210 F Subwoofers
The standard rigging frame can fly up to 20 vertically
arrayed CDR 210 F Subs.
If you are using a combination of CDR 208 S/T
cabinets and CDR 210 F Sub bins on one rigging
frame, calculate the total load using both tables.
Ensure the rigging frame's maximum permissible
load is never exceeded.
Number
Weight [kg]
Weight [lbs.]
1
40
88
2
80
176
3
120
264
4
160
352
5
200
440
6
240
528
7
270
616
8
310
704
9
350
792
10
390
880
11
430
968
12
470
1056
13
510
1144
14
550
1232
15
590
1320
16
630
1408
17
670
1496
18
710
1584
19
750
1672
20
790
1760
Table 2: Weight of the CDR 210 F Sub
3.6 Ground-stacked Mid/High
Enclosures
Ensure that the (inverted) top rigging frame is placed
securely on the ground or stage. Secure the mid/high
stack to prevent slippage!
3.7 Pick Points for Flying
COHEDRA
®
Mid/high Enclosures
Use only the top rigging frame's shackles to attach
motors, chain hoists and straps. Insert them into
the eyelets in the centre rail designed to accept
shackles!
Never use the round pole on the top rigging frame
to attach shackles or mount motors! This pole is
used only for guiding and securing cables.
Use only the bottom rigging frame to curve the array.
Clear the area immediately below arrays of people
before raising or lowering loads.
Lift and lower flown mid/high enclosures smoothly,
avoiding abrupt stops or jerky motions.
Secure the flown mid/high array in place with straps
so that it remains immovable, for example, despite
gusts of wind. Use the eyelets in the bottom rigging
frame to affix straps.
3.8 Structural Modifications of
COHEDRA
®
Rigging Hardware
No structural modifications may be made without
the manufacturer's permission. This also applies
to welding work performed on supporting parts.
Structural alterations require the manufacturer's
written approval. Use original replacement and
wearing parts only.
3.9 Original HK AUDIO
®
Accessories
Use original HK AUDIO
®
parts only (see section
4)! The safety standards authority TÜV has not
certified any other parts for use! Always install parts
in accordance with these installation instructions!
Compile and store all documents pertaining to the
system in a safe place!
3.10 Initiation and Operation
§ 39, VBG 9 A of the German employers' liability
insurance association accident prevention regu-
lations requires that load-carrying equipment be
inspected by a qualified expert and possible defects
be eliminated prior to initial commissioning by the
recipient.
§ 41 VBG 9a requires that load-carrying equipment
be subjected to a non-routine inspection following
damage, repair work and other incidents that can
affect load-carrying capacity.
co_coco_BDA_de_engl_2.indd 25