Hard Reset:

 Factory default  

(Admin+Back for 3 seconds)

Functions:

• Filter banks deleted 

• Admin: Keylock deactivated

• Input assign A/B

• Analog input source 

• Sample rate 96 kHz

• Dig Clk Sync: internal

• Delay unit: ms

• Temperature: 20°C

• Display contrast: 15

• Device name 0

• Max input: + 18 dBu

• Max. 6 dBu (setting for VX 2400)

• IP not reset

Rear Panel Connectors 

14  100-240 V~ / 50-60 Hz Mains

This three-pole non-heating equipment connector with a ground contact con-
nects the FIRNET controller to the mains power supply. The multi-voltage power 
supply unit allows the controller to be connected directly to all mains voltages 
ranging between 100 V and 240 V without requiring transformers and the like. 
Its maximum power consumption is 40 VA, which corresponds to about 175 mA 
maximum current consumption at 230 V mains voltage and about 400 mA at 
100 V. Do not connect the device using anything other than a three-pole con-
nector with a ground contact. The mains outlet must also be equipped with a 
ground contact. Never use damaged cords, plugs, or sockets.

15 GPIO

This 25-pin sub-D port provides four each floating inputs and outputs for future 
firmware versions’ use, for example, to remote-control power amps or switch 
controlled devices. Current firmware does not support this feature.

16  Ethernet PC Control Ports  

Ethernet ports relay remote control and monitoring data between a PC and 
FIRNET controllers via computer networking hardware. The Ethernet X and 
Ethernet II connectors are RJ-45 ports (Input X = for cross input, 
II = parallel input). 

Cabling:

If you do not wish to use further network hardware such as hubs and switches, 
connect the PC’s network port to the first FIRNET’s Ethernet X port using CAT5 
network cable. Then also use a CAT5 network cable to connect the first FIRNET’s 
Ethernet II port to the second controller’s Ethernet X port, and so forth.
 
Use a CAT5 network cable to connect the FIRNET controller to hubs or switches, 
patching the FIRNET controller’s Ethernet II port to the hub or switch’s network 
port. To daisy-chain further FIRNET controllers, connect the first FIRNET’s 
Ethernet X port to the second controller’s Ethernet II port, and so forth.
 
Tip: We recommend that you connect all FIRNET controllers to switches. If you 
do not, and one controller fails in setups comprising several -connected FIRNET 
controllers, the entire networked chain will drop out.

Fig. 31: FirNet™ – Networked FIRNET and PC  

Fig. 32: FirNet™ – Networked hub and PC

 

17  AES/EBU IN Digital Audio Input

Connect signal sources with digital outputs to these three-pin female XLR 
sockets. Pin assignments are pin 1 = ground, pin 2 = signal, and pin 3 = signal. 
The FIRNET controller accepts sampling rates of 48 kHz and 96 kHz, which 
may be selected via a menu option.

Input-Output Signal Routing:

The analog INPUT A – that is, the left channel of the digital AES/EBU signal 
- delivers the signal to OUTPUT A and OUTPUT B. OUTPUT C and OUTPUT 
D receive their signal from analog INPUT B, that is, the right channel of the 
digital AES/EBU signal. You can reroute signals in the LIPAN software’s Admin 
window.

18  AES/EBU OUT Digital Audio Output

The signal patched into the AES/EBU input can be routed through in digital 
format to other devices via this three-pin male XLR port. Pin assignments are 
pin 1 = ground, pins 2 and 3 = signal. The FIRNET amplifi es the incoming digital 
audio signal to preserve signal quality. If a FIRNET controller drops out, the 
signal is routed directly from the digital AES/EBU IN to the digital AES/EBU 
OUT via a parallel circuit.

To select the digital input, go to the Admin menu (press ADMIN once), choose 
the menu option Input Options (press 1x 

S

), and then press ENTER to confi rm:

Menu option - ADMIN/Input Options/ Input Source 

 

Synchronization Ports for Analog Audio Signals:

If you wish to address several FIRNET controllers via their analog inputs, you 
can use digital AES/EBU IN inputs and AES/EBU OUT outputs to synchronize 
these controllers to ensure the audio signal remains coherent.
To do this, connect the first FIRNET controller’s digital AES/EBU OUT to 
the second FIRNET’s digital AES/EBU IN. Then connect the second FIRNET 
controller’s digital AES/EBU OUT to the third FIRNET’s digital AES/EBU IN, 
and so forth. 

Содержание Cadis CAD 115

Страница 1: ...1 Manual 1 0 Cadis English Deutsch...

Страница 2: ...sever al other power consumers The plug socket for the power supply must be positioned near the unit and must be easily accessible PLACE OF INSTALLATION The unit should stand only on a clean horizonta...

Страница 3: ...di corrente deve essere situata nelle vicinanze dell apparecchio e facilmente raggiungibile in qualsiasi momento LOCALI DI COLLOCAMENTO Opportuno collocare l apparecchio su una superficie pulita e or...

Страница 4: ...of Figures Fig 1 CAD 208 5 Fig 2 Subwoofer CAD 115 Sub 6 Fig 3 CAD 208 case and CAD 115 dolly 7 Fig 4 12 flown CAD 208 mid high enclosures 10 Fig 5 CAD 208 mid high enclosure with integrated rigging h...

Страница 5: ...on the height of the array The CAD 208 is thus able to serve as a fullrange speaker for pure speech rein forcement applications We recommend using at least two enclosures for this Connections The conn...

Страница 6: ...pins are wired in parallel Pin assignments are pin 1 mid high 1 mid high 2 sub 2 sub 2 2 1 Technical Data CAD 115 Sub You ll find frequency measurements on page xxx Nominal power handling AES 6 dB cr...

Страница 7: ...8 Width 66 cm 26 Depth 46 cm 18 1 8 Height incl casters 121 cm 47 5 8 Weight empty 42 5 kg 93 7 lbs Case 8x CAD 208 Width 85 cm 33 1 2 Depth 67 cm 26 3 8 Height incl casters 121 cm 47 5 8 Weight empty...

Страница 8: ...ply with BGV C1 accident prevention regulations and that the safety standards authority T V has certified them for the full load see table 1 Prior to every installation inspect all components to ensur...

Страница 9: ...8 2x CAD 115 Sub 8 CAD 208 Caution Flying more than two subwoofers in stacked array with the connector frame voids the safety standards authority T V s certification CAD 115 subwoofers and CAD 208 mid...

Страница 10: ...n compression mode integrated rigging hardware on the side and back for flying CADIS enclosures four quick release pins per CAD 208 for connecting the enclosure to another enclosure or the rigging fra...

Страница 11: ...connects individual CAD 208 cabinets En sure this pin is inserted otherwise the enclosures will not be connected to each other and may swing forward 4 1 1 Preparations The following section describes...

Страница 12: ...in hoist that will later serve to pull back the ends of the array and curve out its front face Do this now Tip If you intend to rig more CAD 208 enclosures we recommend that you attach all the require...

Страница 13: ...S array secure it against gusts of wind or unintended twisting using two lashing straps or ropes 4 2 Fixed Mode To determine the set angle between two enclosures in fixed mode you must insert one pin...

Страница 14: ...ging yoke to the bottom subwoofer by inserting four pins into the enclosure s recessed rigging rails You may mount the first mid high enclosure to the rigging yoke in fixed or in compression mode For...

Страница 15: ...Once you have checked all cabinets successfully turn up all gain knobs one after the other Start with the channel 1 gain knob for the top mid high units and then turn up the channel 2 gain knob and so...

Страница 16: ...ent application in a virtual simulation that is without having to map the room s complexities and without setting up testing and adjusting the system until you find the optimum solution Note Bear in m...

Страница 17: ...4 in the last address block However the PC and connected controller may not have the same numerals in the last block Viewing the controller s IP address Network environment double click network link S...

Страница 18: ...s powered up and then the display indicates current speaker selection settings and the LAN status Once you begin navigating ad justable parameters it shows values pertaining to these parameters FirNet...

Страница 19: ...ss If the red LED lights up set the FIRNET s input gain to a higher value see the section Setting Peak AD Level in the Adjusting Pa rameters chapter or reduce the source audio device s output level Be...

Страница 20: ...hub or switch s network port To daisy chain further FIRNET controllers connect the first FIRNET s Ethernet X port to the second controller s Ethernet II port and so forth Tip We recommend that you con...

Страница 21: ...se these three pin XLR male sockets to route output signals to power amps Pin assignments are pin 1 ground pin 2 signal and pin 3 signal These electronically balanced connectors output impedance is 35...

Страница 22: ...s Five menu options are available for editing individual parameters Simply press the appropriate key to select a menu Speaker Auswahl A quick run down on how to select the speaker series and the right...

Страница 23: ...Selecting the Input Phase Position Selecting the Output Phase Position Admin Adjusting the Remaining Parameters Key Lock Preventing Unauthorized Access Locking Keys Input Options Utilities Delay Tempe...

Страница 24: ...ut level Variable 6 12 18 and 24 dBu Dynamic range output 125 dB A Mains voltage connector Three pole non heating equipment connector Mains voltage frequency 100 to 240 V 50 60 Hz Power consumption 40...

Страница 25: ...60158 9760158 Rigging connector CAD 115 Sub 1006092 Front grille CAD 115 Sub 3400176 3400181 Front grille CAD 208 3400175 3400182 Rubber foot CAD 115 Sub 9760009 9760009 Quick release pins 9760184 976...

Страница 26: ...grille s four Phillips head screws on the housing s left and right panels Lift the grille towards you to carefully remove it from its frame Unfasten and remove the ten Torx T25 screws on the baffle bo...

Страница 27: ...llrange CAD208 4 fullr 1 06 01 09 12 x CAD 208 6 x CAD 115 CAD208 4 100Hz 1 06 01 09 16 x CAD 208 Fullrange CAD208 8 fullr 1 06 01 09 16 x CAD 208 8 x CAD 115 CAD208 8 100Hz 1 06 01 09 Table 5 CADIS F...

Страница 28: ...bersicht der Filters tze CADIS FIRNET Controller 51 Verzeichnis der Abbildungen Abb 1 CAD 208 29 Abb 2 Subwoofer CAD 115 Sub 30 Abb 3 CAD 208 Cases und CAD 115 Rollbrett 31 Abb 4 12 CAD 208 Mid High...

Страница 29: ...zfrequenz ndert sich je nach L nge des Arrays auf 70 Hz F r ausschlie liche Sprachbeschallung kann die CAD 208 somit bereits Full range eingesetzt werden mindestens 2 Topteile empfohlen Anschl sse Die...

Страница 30: ...ung Beide Anschl sse sind vierpolig parallel ver schaltet Die Anschlussbelegung lautet pin 1 Mid High 1 Mid High 2 Sub 2 Sub 2 2 1 Technische Daten CAD 115 Sub Frequenzmessungen finden Sie auf Seite x...

Страница 31: ...AD 208 Breite 66 cm 26 Tiefe 46 cm 18 1 8 H he auf Rollen stehend 121 cm 47 5 8 Gewicht ohne Boxen 42 5 kg 93 7 lbs Case 8x CAD 208 Breite 85 cm 33 1 2 Tiefe 67 cm 26 3 8 H he auf Rollen stehend 121 c...

Страница 32: ...tsystem T V abgenom men Die Vorschriften zum Rigging System beinhalten die Installation gem nachfolgender Spezifikationen Vergewissern Sie sich vor der Montage dass die Befestigungspunkte im B hnendac...

Страница 33: ...mmif e zeigen nach unten Anzahl Gewicht kg lbs 1 38 83 8 2 76 167 6 3 114 251 3 4 152 335 1 5 190 418 9 6 228 502 7 Tabelle 2 Gewichte der CADIS Subwoofer CAD 115 Sub Die Kombination von CAD 115 Sub u...

Страница 34: ...n dient auch als Basis f r Groundstack Varianten ein optionaler zweiteiliger Zurrgurt zum Curven des Systems im Compression Mode seitlich und r ckw rtig integrierte Flugmechanik der CADIS Boxen 4 Kuge...

Страница 35: ...ng Link hergestellt Dieser muss auf jeden Fall eingesteckt sein ansonsten sind die Boxen nicht miteinander verbunden und k nnen nach vorne durchschwingen 4 1 1 Vorbereitungen Im folgenden wird zun chs...

Страница 36: ...eite des Systems bereits jetzt an einem der Sch kel des Flugrahmens zu befestigen Tipp Sollen noch weitere CAD 208 Boxen montiert werden empfiehlt es sich alle ben tigten Lautsprecherkabel bereits jet...

Страница 37: ...wegungen durch Windst e bzw unbeabsichtigtes verdrehen mit zwei Zurrgurten oder Seilen 4 2 Fixed Mode Zum Einstellen des Curving Winkels zwischen zwei Boxen im Fixed Mode muss der eine Pin Set Angle e...

Страница 38: ...ub an Befestigen Sie den Flugb gel nun mit 4 Pins an den eingelassenen Flugschienen im Sub Das erste Topteil kann sowohl im Fixed Mode als auch im Compression Mode am Flugb gel befestigt werden F r ei...

Страница 39: ...nden drehen Sie alle Gainregler nacheinan der auf Beginnen Sie wieder mit Channel 1 der oberen Mid High Boxen dann Channel 2 usw dazu drehen Bei jedem zus tzlichen Kanal der in Betrieb genommen wird s...

Страница 40: ...htung ermitteln ohne diese praktisch aufzubauen zu testen und dann so lange zu ver ndern bis Sie eine optimale L sung gefunden haben Hinweis Ein m glichst genaues Ausmessen der Raumgeometrie vor allem...

Страница 41: ...ung Scroll Down und Rechtsklick auf TCPIP Eigenschaften IP Adressbereich Bei nderung der IP Adresse muss der PC neu gestartet werden Die voreingestellte IP Adresse Ihres Controllers k nnen Sie nach de...

Страница 42: ...nt der Startbildschirm danach werden die aktuellen Einstellungen f r Speakerauswahl und LAN Status ange zeigt Wenn Sie die einstellbaren Parameter ansteuern werden entsprechend andere Informationen an...

Страница 43: ...t Abschnitt Einstellung des maximalen AD Pegels im Kapitel Einstellung der Parameter des FIRNET oder reduzieren Sie den Ausgangspegel des vorgeschalteten Audioger tes Achten sie hierbei auch auf die e...

Страница 44: ...Controller mittels CAT5 Netzwerkkabel mit einer Netzwerkbuchse des Hub bzw Switch verbunden Sollen weitere FIRNET Cont roller am ersten Ger t angeschlossen werden wird dann der Anschluss Ether net X d...

Страница 45: ...best tigen mit ENTER Men punkt ADMIN Analog Levels Durch die Verwendung gestackter AD Wandler betr gt die Eingangsdynamik des FIRNET 128 dB A Hinweis Nach einem Firmware Update m ssen die Analog Leve...

Страница 46: ...ting aktueller Input aktuelle Sample rate aktueller Synchronisationsstatus aktuelle Firmware Version Einstellung der Parameter Die Controllermen s Zum Bearbeiten der einzelnen Parameter stehen f nf Me...

Страница 47: ...e in den Eing ngen Einstellung der Phasenlage in den Ausg ngen Admin Einstellung der brigen Parameter Keylock Tastensperre zum Schutz vor Zugriff gegen unberechtigte Personen Aktivierung der Tastenspe...

Страница 48: ...ngsimpedanz 35 Ohm maximaler Ausgangspegel schaltbar auf 6 12 18 oder 24 dBu Ausgangsdynamik 125 dB A Anschluss Netzspannung dreipoliger Kaltger teanschluss Netzspannung frequenz 100 bis 240 V 50 60 H...

Страница 49: ...mifu CAD 115 Sub 9760009 9760009 Kugelsperrbolzen quick release pin 9760184 9760184 Leergeh use CAD 115 Sub 4000559 4000565 Leergeh use CAD 208 9590150 4000558 Griff CAD 115 Sub 9760189 9760190 R ckse...

Страница 50: ...und Einbau von Ersatzlautsprechern unbedingt auf die richtige Polung Der Plus Pol der 8 Lautsprechers ist mit einem roten Punkt gekennzeichnet 3 2 Schwingspulen der 1 Treiber Um die Schwingspule zu we...

Страница 51: ...z 1 01 06 09 8 x CAD 208 Fullrange CAD208 8 fullr 1 01 06 09 8 x CAD 208 4 x CAD 115 CAD208 8 100Hz 1 01 06 09 12 x CAD 208 Fullrange CAD208 4 fullr 1 01 06 09 12 x CAD 208 6 x CAD 115 CAD208 4 100Hz...

Страница 52: ...208 Impedance 4 x CAD 208 Max SPL CAD 208 Directivity vertical 2D CAD 208 Directivity horizontal 2D CAD 208 Phase Responce 125 Hz Oktav 250 Hz Oktav 500 Hz Oktav 1000 Hz Oktav 2000 Hz Oktav 4000 Hz O...

Страница 53: ...53 Deutsch English CAD 115 Sub FQ Halbraum CAD 115 Sub Phase Response CAD 115 Sub Max SPL CAD 115 Sub Impedance...

Страница 54: ...Cadis Manual 1 0...

Страница 55: ...55...

Страница 56: ...stfach 1509 66595 St Wendel Germany info hkaudio com www hkaudio com International Inquiries fax 49 68 51 905 215 international hkaudio com Technische nderungen vorbehalten Copyright 2009 Music Sales...

Отзывы: