46
C19UC101-1801
5.3 Fuse
If encountered the following two situations, please try to open the controller cover and
check whether the internal fuse has melted:
1.
If unable to start the controller, please follow the steps below to
replace the fuse:
1.
Remove 11 pieces of M4X0.7PX12L Phillips screws on the
cover and remove the cover.
2.
Check FUSE1, FUSE2, FUSE3 on RCBCDZ023.
3.
Remove the protective cover of the fuse, if the fuse is melted,
replace a new fuse.
4.
The specification of FUSE1, FUSE2, FUSE3 are 15A 5*20mm
glass fuse.
5.
After replacing a new fuse, cover the fuse with protective cover.
6.
Check FUSE1 on RCBCDZ033, if the fuse is melted, please
replace a new fuse LITTELFUSE 0297005 5A
7.
Close the cover and secure the screws.
Содержание RCD403-GB