Assembly and connection
49
Assembly Instructions
Linear Axes HM-S and HT-S
HMS_HTS-01-0-EN-1905-MA
Secure the motor against falling.
Place the motor flat on the motor adapter plate AM.
Fasten the motor in accordance with the manufacturer’s specifications.
Fig. 6.47
Bolting the motor to the HT-S linear table
AM
Take care to slide the motor on straight so that the preset L measurement does not change.
NOTE
Remove the seal plug from the hole on the side of the motor adapter plate AM.
By moving the carriage, shift the clamping hub to the position in which the screw(s) of the clamping hub can be reached
through the bore.
HT150S/HT200S:
Tighten the clamping hub’s bolt through the bore with the tightening torque shown in Table 6.16.
HT100S/HT250S:
Tighten both screws of the clamping hub one after the other through the bore. First, position the screw on the 1st side,
then tighten the screw on the 2nd side and then on the 1st side with the tightening torque shown in Table 6.16.
Insert the seal plug back in the hole.
Fig. 6.48
Tightening the clamping hub on the motor shaft
The motor has now been installed.
Содержание HM-S
Страница 99: ......