Assembly and connection
35
Assembly Instructions
Linear Axes HM-S and HT-S
HMS_HTS-01-0-EN-1905-MA
Clean mounting surfaces at the carriage.
Clean the mounting surface of the load.
If necessary, use centring sleeves.
Position the load on the carriage of the linear axis.
Tighten the mounting bolts crosswise.
Check the free movement of the load over the entire stroke.
Lock the bolts.
The imposed load has now been installed.
Fig. 6.23
Securing the load with centring sleeves (HM-S linear module as an example)
Precision requirements for the imposed load’s mounting surface.
0.02
6.3 Mounting the limit switches
The limit switches are available as an N/C or N/O contact. The limit switch can be secured directly in the limit switch groove
(T groove) with the provided M3 bolts and nuts. The limit switches can be mounted on the left or right.
If necessary, remove the green decorative strip from the upper T groove.
Push two nuts into the upper T groove through the notch at the drive block.
Attach the limit switch with two bolts (in the case of the axis sizes HM040S/HT100S, the spacer plate must also be
installed between the limit switch and axis, see Fig. 6.24). First leave the two bolts untightened.
Push the limit switch to the required position, and press it up slightly.
Tighten the bolts. The tightening torque is 0.5 Nm.
The limit switches have now been installed.
Содержание HM-S
Страница 99: ......